Validity and ATEX certi ed versions. additional ATEX instruction must also be read. ATEX certi ed pumps are indicated by Ex in the designation - example PAH 20 Ex. Non ATEX versions ATEX certi ed versions PAH 20 Code no.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps • If any changes are made without written Introduction General The PAH pumps and pump units are manufac- approval the warranty will automatically tured by Danfoss A/S, and are sold and marketed become void.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Web: hpp.danfoss.com 1.3 Manufacturer and customer service Your local Danfoss pump distributor can be address: found on our homepage. Danfoss A/S High Pressure Pumps 1.4 Country speci c information Nordborgvej 81, 1.4.1 United Kingdom...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps It is always the system builders´ responsibility • Do not try to lift the pump unit manually; that the system design does not cause any kind most of the pumps weigh more than...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps 3.7 Filtration 3.9 Air bubbles Large bubbles in a pressurised system can result (10µm absolute [β ≥ 5000]) Requirements are speci ed in appendix 1, Data in damage to piping, equipment and the pump.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Pumps which have a weight above 20 kilos (see Wrong lifting: appendix 1, Data sheet) must be handled by using lifting eyes and slings. When lifting the pump unit, one sling must be attached to the electric motor and one sling around the pump.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Installation and commissioning 5.1 Important dimensions Physical dimensions and connections of the 5.3 Fluid temperature pump unit are described in appendix 1, Data Before start-up, the uid and pump housing sheet.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps 5.6 Pre mounting checklist, based on Danfoss preferred system design Check points Comment OK ? Ensure that the environmental conditions are safe. See Arrival inspection, transportation, handling, lifting and storage, chapter 4.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps 5.12 Ensure free ow Ensure free ow from relief valve (table 1, item 5.6, CP 8). A blocked relief valve can cause excessive build-up of pressure and thereby cause •...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Operation of motor pump unit 6.1 General safety information Before inspecting the pump unit, read the Safety restarted. Contact the maintenance chapter 2 in this user manual. department. Drop in ow and/or pressure – may indicate 6.2 What to listen and look for...
Page 14
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Slowly unscrew and remove the bolts and gaskets from the inlet/outlet hoses or pipes, be careful about jets of water. Be aware that the system can be pressurized. Attach the lifting equipment to the pump unit.
Page 15
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Electrical Troubleshooting and hazard scrapping criteria 8.1 General safety information Before inspecting the pump unit, it is necessary 8.4 Electrical failure to read and understand this user manual, If the wiring of the electric motor is incorrect or especially the Safety chapter 2.
Page 20
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Data sheet Contents Table of Contents Introduction ................20 Bene ts.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Data sheet Below sectional drawing is an example of a PAH pump. 1: Shaft sealing 2: Mounting ange/ housing with bearing 3: Retaining ring 4: Piston/shoe 5: Valve trust plate...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Data sheet The ow (Q ) at various pressure (p ) can be At zero pressure the true ow equals the Flow calculated with the following equation: theoretical ow Q (th) –...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Data sheet The required motor power can be calculated by Motor requirements using the following equation: n x V x p 600.000 x η P: Power (kW) M: Torque (Nm) η: Mechanical e ciency...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Data sheet See the gure below for instructions on how to motor or combustion engine. Installation mount the pump and connect it to an electric A: Flexible coupling B: Bell housing...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Data sheet inlet temperature is higher than the set 7.3 Open-system design value. Inlet line: Hoses: Dimension the inlet line to obtain mini- Always use exible hoses (5) to minimize mum pressure loss (large ow, minimum vibrations and noise.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Data sheet Closed-system design Hoses: Always use exible hoses (6) to minimize vibrations and noise. Inlet line: Dimension the inlet line to obtain mini- Inlet pressure: mum pressure loss (large ow, minimum...
Operating guide Data sheet Installation, Operation and Maintenance Manual for PAH 20-100 pumps Danfoss PAH pumps are designed for long Other factors that a ect pump performance and Service periods of service-free operation to ensure low lifetime include: maintenance and life cycle costs. Provided that the pump is installed and operated according to •...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Instruction System design Hoses: Always use exible hoses (6) to minimize 2.1 Closed-system design vibrations and noise. Inlet line: Inlet pressure: Dimension the inlet line to obtain mini- In order to eliminate the risk of cavitation...
Operating guide Instruction Installation, Operation and Maintenance Manual for PAH 20-100 pumps inlet temperature is higher than the set 2.2 Open-system design value. Inlet line: Dimension the inlet line to obtain mini- mum pressure loss (large ow, minimum Hoses: pipe length, minimum number of bends/...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Instruction 2.3 General guidelines for calculation of pressure losses The suction conditions can be optimized according to below guidelines. In smooth pipes and hoses In 90° bends 2.4 General comments on...
Operating guide Instruction Installation, Operation and Maintenance Manual for PAH 20-100 pumps We recommend a separation (“wall”) to separate Monitoring the inlet from the outlet end of the tank. It is recommended to continuously monitor the following conditions: • Water level in the tank •...
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Instruction 3.4 Protection from too high pressures The pump should be protected against too high The opening characteristics of the valve must not pressure by means of a pressure relief valve or a...
Operating guide Instruction Installation, Operation and Maintenance Manual for PAH 20-100 pumps Before start-up, loosen the top bleeding plug “C”. Initial start-up When water appears from the bleeding plug, retighten the plug. With its inlet line connected to the water supply or the tank, the pump is now started with open outlet port.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Instruction 5.6.2 Open-ended systems with water supply 5.6.3 Open-ended systems with direct water from tank. supply. Empty the tank of water and empty the Disconnect the water supply to the pump.
Page 44
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Motor Manual etc.) using suitable tools, never hit the drive components General with a hammer as this will cause damage to the bearing. This manual concerns the following types of standard...
Page 45
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Motor Manual connections must be checked and tightened if necessary. The table values are based on an ambient temperature of Bearing size and type are specified on the rating plate. Motor 25°C.
Page 51
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Parts list This parts list provides an overview of the General content of the various service sets as well as exploded views of the pumps. for PAH pumps both non ATEX and ATEX certifiec.
Page 52
Operating guide Parts list Installation, Operation and Maintenance Manual for PAH 20-100 pumps Spare parts list for PAH 20/25/32 Pos. Qty. Designation Material Shaft bush, torpedo Press tool for 28 mm shaft Mounting screw Housing PAH 1.4301 1.4401 Plug 1.4301...
Page 54
Operating guide Parts list Installation, Operation and Maintenance Manual for PAH 20-100 pumps Spare parts list for PAH 50/63/70/80/100 Pos. Qnt. Designation Material Shaft bush, torpedo Press tool for 35 mm shaft Mounting screw Housing 1.4301 1.4401 Plug 1.4301 O-RING Swash plate 1.4057...
Page 58
Operating guide Guideline Installation, Operation and Maintenance Manual for PAH 20-100 pumps Table of Contents Table of Contents Trouble shooting sh bone chart ............61 No ow/no pressure.
Operating guide Guideline Installation, Operation and Maintenance Manual for PAH 20-100 pumps No ow/no pressure Cause Remedy Comments If no water comes out of the pump: Mount a low pressure switch in front of the 1.1 Dry running (no water supply to the pump) pump and check its set point/ function.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Guideline Reduced ow/reduced pressure Cause Remedy Comments 2.1.1 Dismantle the pump. 2.1 Wear on pump Typical signs of wear: Large internal leakage due to: 2.1.2 Check valve plate. Polished surface all over the swash plate.
Operating guide Guideline Installation, Operation and Maintenance Manual for PAH 20-100 pumps High torque on electric motor Cause Remedy Comments 3.1.1 Check for blocked nozzles or a faulty Pressure changes due to ow restrictions. This 3.1 Too high outlet pressure from pump adjusted relief valve.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Guideline Noise from pump Cause Remedy Comments 4.1.1 Ensure that the entire inlet line is bled Small air bubbles will accumulate and create 4.1 Air in uid before starting up the system.
Operating guide Guideline Installation, Operation and Maintenance Manual for PAH 20-100 pumps Noise from installation Cause Remedy Comments 5.1.1 Use exible hoses at inlet/outlet connec- Non- exible connections mounted directly on 5.1 Inlet/outlet connections (hoses/pipes) tions. the frame will cause even small pressure pulsations from pump and create vibrations in the system/plant.
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Guideline Typical signs of wear 6.1 Valve plate Picture 1 A normally worn valve plate has no marks/scratches but only a slightly polished surface. No scratches or marks should be felt. The surface must be at and level.
To check this, please see item 6.1, picture 3. If the surface has any marks/scratches, it is worn/damaged and a new one is required. Please contact Danfoss High Pressure Pumps sales o ce for further infor- mation. 66 | 180R9380 | AQ213286502970en-000801...
Page 70
Pump location Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Design Pump always to be placed below water Pump location above water surface surface level level will cause damage Choice of material Suction conditions Iron Rubber Copper...
Page 71
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Installation Assembly of coupling Impurities Never use force when assembling the Prior to installation, burrs and chips and Chips or other impurities in the system The coupling must be easy and simple...
Page 72
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Wiring Starting procedure Cleaning procedure 1. Fill cold water into the system via the return lter and Level indicator bleed the pump (Power Packs PPH 4 - 6.3 - 10 and 12.5 are self-bleeding) 2.
Page 73
Trouble shooting Open ended water systems No water supply Is the water supply ok? Is water supplied to the pump? Is water coming Is the electric motor of Lower inlet Is the water in the tank out of the tap? the pump unit rotating? temperature or very hot? Ie above 50...
Page 74
Operating guide Installation, Operation and Maintenance Manual for PAH 20-100 pumps Trouble shooting Closed water systems The system does not work Is there su cient water in the tank? Is the water in the Is the electric motor of tank very hot?