Transportation
Cut
Supply
air
A
C
Horizontal projection
Supply
air
Fig. 6
Minimum distances in the technical room
(dimensions in mm)
A
B
C
D
E
F
G
H
I
Tab. 7
Minimum distances in the technical room
VITOBLOC 200 BM-366/437 Assembly instructions
Exhaust gas
D
Extract air
Gas
Heating water
Condensate
Heating water
Condensate
B
Gas
Extract air
Extract air
Condensate
Condensate
Exhaust gas
1,000 mm
2,000 mm
7,000 mm
4,708 mm
2,070 mm
3,500 mm
1,500 mm
1,650 mm
4,650 mm
3.5
Removing the transport securing
devices
Remove the packaging and send it for recycling.
Remove four transport securing devices at the
elastic supports of the engine and alternator
(Fig. 7)
Fig. 7
Remove four transport securing devices at the
elastic supports of the engine and alternator
CAUTION
Always remount the transport locking
device when the block-type thermal
power station is removed after final
shut-down. Otherwise, there is a risk
that the motor-generator unit will tear off
from the basic frame if not transported
vertically, which can endanger the
transport personnel.