Mtbf - Kontron nanoETXexpress-SP User Manual

Hide thumbs Also See for nanoETXexpress-SP:
Table of Contents

Advertisement

3.9 MTBF

The following MTBF (Mean Time Before Failure) values were calculated using a combination of manufacturer's test
data, if the data was available, and the Telcordia (Bellcore) issue 2 calculation for the remaining parts.
The calculation methode used is "Telcordia Method 1 Case 3" in a ground benign, controlled environment (GB,GC).
This particular method takes into account varying temperature and stress data and the system is assumed to have not
been burned in.
Other environmental stresses (extreme altitude, vibration, salt water exposure, etc) lower MTBF values.
System MTBF (hours): 209423 @ 40°C
Fans usually shipped with Kontron Embedded Modules GmbH products have 50,000-hour
typical operating life. The above estimates assume no fan, but a passive heat sinking
arrangement Estimated RTC battery life (as opposed to battery failures) is not accounted
for in the above figures and need to be considered for separately. Battery life depends on
both temperature and operating conditions. When the Kontron unit has external power;
the only battery drain is from leakage paths.
Connector The pin outs for nanoETXexpress-SP Interface Connectors X1A and X1B are documented for convenient
reference. Please see the COM Express™ Specification and COM Express™ Design Guide for detailed, design-level
information.
20
nanoETXexpress-SP/Specification

Advertisement

Table of Contents
loading

Table of Contents