Leveling Information - U-Line UCDE215 User Manual & Service Manual

15” beer dispenser
Hide thumbs Also See for UCDE215:
Table of Contents

Advertisement

USER GUIDE
Setting CO2 Pressure
To minimize foam for most beverages the pressure should
be set between 8-12 PSI.
Set the pressure by turning the handle on the front of
the regulator counterclockwise until it is all the way out.
This will turn the regulator off.
Turn the valve on the bottom of the regulator to the
side to ensure no CO2 will pass through the regulator.
Pull the pin on the side of the coupler to release
built up pressure from the keg. Open the faucet. Nothing
should come out initially as there is no pressure to the
keg.
Place a container under the faucet and open the valve
on the bottom of the regulator.
Turn the handle clockwise with the faucet open and
your beverage will start to pour. Stop turning when you
get the best flow rate. This method should prevent your
regulator from creeping.
If you are dispensing at altitude, you will need to increase
your output pressure by one pound for every 2,000 feet of
elevation above sea level.
Handle
Valve
General Installation

LEVELING INFORMATION

1.
Use a level to confirm the unit is level. Level should be
placed along top edge and side edge as shown.
2.
If the unit is not level, shim as needed.
3.
Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
CAUTION
!
To comply with applicable federal, state, and
local codes, it may be necessary to caulk the
refrigerator to the floor.
CASTERS (optional)
1.
Remove grille and back panel to access nuts.
2.
Remove each nut and unscrew each leg.
3.
Install each caster and secure with nut. Tighten with
included wrench.
4.
Replace grille and back panel.
When ready to use, see FIRST USE section in this
manual.
16
u-line.com

Advertisement

Table of Contents
loading

Table of Contents