Page 1
USER GUIDE & SERVICE MANUAL Dispensers UHDE215 15” Solid Door Cold Coffee Dispenser ● ●...
Page 2
USER GUIDE & SERVICE MANUAL u-line.com Table of Contents Intro Parts Ordering Replacement Parts Safety R600a Specifications Safety and Warning System Diagnosis Guide Disposal And Recycling Compressor Specifications Troubleshooting Extended Installation Control Operation - Service Environmental Requirements Thermistor Electrical Defrost Cutout &...
® to preserve the right product, in the right place, at the right temperature. Since 2014, U-Line has been part of the Middleby family of brands. All products are designed, engineered, and assembled in Milwaukee, Wisconsin, USA, and select products are available worldwide.
USER GUIDE u-line.com Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
USER GUIDE u-line.com Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal,...
USER GUIDE u-line.com Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce...
Page 7
USER GUIDE u-line.com Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
(1,272 mm) 45 ⁄ ” (1,165 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit FRONT does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, and clearance is required for an electrical connection in the rear.
USER GUIDE u-line.com Anti-Tip Bracket Slide unit out so screws on top of unit are easily accessible. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
5. 2.5-gallon ball tap keg (you may use 3-gallon or 5-gallon keg) 6. Drip tray 7. Cleaning solution (2-ounce packet) (Additional cleaner, ULACOFFEECLEAN, is available at u-line.com) Safety and Warning Required (not included): Nitrogen tank with food grade nitrogen - available at WARNING your local gas supplier.
Page 11
USER GUIDE u-line.com Install Tower on Free-Standing Refrigerator If your refrigerator is new out of the box, do not remove all Screw the handles onto the faucets and continue to the protective film on the stainless exterior until the tower assemble and connect regulator to Nitrogen tank.
Page 12
USER GUIDE u-line.com Install Tower on Countertop (See template on next page) Note: These instructions are designed for a standard 36" countertop application. Note: For a customized fit, it may be necessary to acquire screws that are sized to the thickness of your countertop.
Page 13
USER GUIDE u-line.com Template for Countertop Installation Note: Verify template has printed true to scale - double check hole dimensions and placement. 1 Inch 7 - 1⁄2“ To side of unit 1⁄4” HOLE 2-3⁄4” HOLE 14 - 1⁄4” To front face...
Page 14
USER GUIDE u-line.com Assemble and Connect Regulator Connect Keg to Dispenser Tower to Nitrogen Tank Attach black nitrogen coupler of the liquid jumper line Attach ball valve to tank regulator. Tighten with to keg. With your thumb on top of the coupler, pull an adjustable wrench.
Page 15
USER GUIDE u-line.com Attach other end of hose to the single connection Attach gray coupler of the gas jumper line to keg. within the beverage tower. With your thumb on top of the coupler, pull up on collar and press coupler down firmly onto in valve.
USER GUIDE u-line.com Connections When complete, the connections should look like this: Infuser Regulator Tank Regulator Nitrogen Tank Filter Assembly LEVELING INFORMATION Use a level to confirm the unit is level. Level should Confirm the unit is level after each adjustment...
USER GUIDE u-line.com Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. Removing the grille Note: Grille and display are attached. The length of the display wire is sufficient to allow access to the front base components.
USER GUIDE u-line.com Door Swing Wall 2-1/8" Min. (54 mm) 90° Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless Steel models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall.
USER GUIDE u-line.com Door Adjustments TO REVERSE THE DOOR HINGE COVER Hinge cover included with the literature bag is optional. To install hinge cover: Press hinge cover squarely over hinge. Hinge Cover Remove grille: Remove the grille (see GRILLE INSTALLATION section of this guide).
Page 20
USER GUIDE u-line.com Remove door by tilting forward and lifting door off Install top hinge and door: bottom hinge. Retain shoulder washers; they will be reused. Use a Philips screwdriver to remove hinge pin and reinstall on the opposite surface of the hinge.
If the temperature displayed is different than selected, the unit is progressing towards the selected temperature. Time to reach set point varies based upon ambient temperature, temperature of product loaded, door openings, etc. U-Line recommends allowing the unit to reach set points before loading.
Page 22
USER GUIDE u-line.com To adjust pressure, loosen locking nut, turn adjusting screw until desired pressure is reached, and retighten locking nut. Regulated Gauge Tank Pressure Gauge Locking Adjusting Screw On infuser regulator, pull out middle knob to unlock then turn knob until needle points at 7 - turn right to increase;...
USER GUIDE u-line.com Dispensing Coffee The left tap delivers still cold brew which is refreshing and less acidic than hot coffee. The right tap delivers nitrogen-infused coffee which is the ultimate cold brew experience. Thousands of micro-nitrogen bubbles are infused as the coffee is dis- pensed.
USER GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and hold for 5 seconds Unit will turn On or OFF When the display is flashing, press Adjust Temperature Press and release adjust the set point temperature. Note: temperature displayed is the actual temperature inside unit Toggle between º...
USER GUIDE u-line.com Airflow and Product Loading AIRFLOW External • Do not block the front grille - no additional clearance around sides, top or rear of unit is needed for ventilation • Do not install behind a closed door Internal •...
USER GUIDE u-line.com Cleaning INTERIOR CLEANING Disconnect power to the unit. Stainless Models Clean the interior and all removed components using a mild nonabrasive detergent and warm solution applied with Stainless door panels, handles and frames can discolor a soft sponge or non-abrasive cloth.
Filter a solution of water and ULACOFFEECLEAN. One packet of ULACOFFEECLEAN (Stera-Sheen®) was included with your product and more can be purchased at u-line.com. Line and System Cleaning Notice Remove the contents, clean the keg with water warm Confirm system is not pressurized by turning soapy water, and rinse.
USER GUIDE u-line.com Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary.
If the unit will be exposed to temperatures of 40 F (5 C) or less, the steps above must be followed. For questions regarding winterization, please call U-Line at 414.354.0300. CAUTION Damage caused by freezing temperatures is not covered by the warranty. Extended Non-Use...
BEFORE CALLING FOR SERVICE • Condenser Fan: Air moving through a condenser may be heard. If you think your U-Line product is malfunctioning, read the CONTROL OPERATION section to clearly understand the • Automatic Defrost Drain Pan: Water may be heard function of the control.
USER GUIDE u-line.com u-line.com CHECKING PRODUCT TEMPERATURE Causes which affect the internal temperatures of the cabinet include: • Temperature setting. • Ambient temperature where installed. • Installation in direct sunlight or near a heat source. • The number of door openings and the time the door is open.
The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
Claims must be submitted online at • Final billing - Remodel www.U-LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
Page 35
USER GUIDE u-line.com Parts UHDE215-SS03A ANTI-TIP BRACKET 80-54221-00 BACK PANEL, 2 PCS, 15" 80-55559-00 COMPRESSOR ASSEMBLY 80-55548-00 CONDENSER ASSEMBLY 80-55453-00 CONDENSER FAN 80-54014-00 17 18 CONTROL ASSEMBLY 80-55552-01 DOOR 80-55560-00 DRAIN PAN 80-54524-00 DRAIN TROUGH* 80-55455-00 DRIER 80-54055-00 DROP IN INVERTER, 120V...
Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
Page 37
Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
Page 38
USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
Page 40
USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
USER GUIDE u-line.com System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold...
USER GUIDE u-line.com Compressor Specifications FMXA9C REFRIGERANT R600A DANGER VOLTAGE 230 VAC FREQUENCY 43-134 Hz START WINDING 20 Ohm at 77 Electrocution can cause death or serious injury. RUN WINDING 20 Ohm at 77 Burns from hot or cold surfaces can cause serious injury.
• Automatic Defrost Drain Pan: Water may be heard U-Line Corp, “Customer Care Facility” at +1.800.779.2547 dripping or running into the drain pan when the unit is for assistance. in the defrost cycle.
Page 44
USER GUIDE u-line.com TROUBLESHOOTING GUIDE Concern Potential Causes Action Not Cooling Compressor overheating Verify proper air flow through condenser. Is condenser clean? Confirm condenser fan operation. Compressor not operating Test overload and relay, replace as needed. Compressor operating - no cooling Refer to System Diagnosis Guide.
USER GUIDE u-line.com MAIN CONTROL CAUTION The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose Precautions must be taken while working with the board for any suspected failures before attempting live electrical equipment.
Page 46
USER GUIDE u-line.com Control Operation-Service UI BUTTON LAYOUT Up Button -Increases temperature -Navigates through service menu -LED activated with button activation Down Button -Decreases temperature -Navigates through service menu -LED activated with button activation Light Button -Activates light for 3 hours on select models...
USER GUIDE USER GUIDE u-line.com u-line.com Thermistors Thermistor Thermistor Resistance Data Thermistor Resistance Data Nominal Resistance Thermistors are used for various temperature readings. Temp (F) Temp (C) Thermistors are used for various temperature readings. (OHMS)* Thermistors provide reliable temperature readings using a...
Page 48
USER GUIDE u-line.com Defrost Outdoor units defrost every 12 hours of compressor runtime for 45 minutes. If you have verified that the unit does not have an ambient air leak, utilize the Control Operation - Service section and adjust unit to defrost...
USER GUIDE u-line.com Remove Fan and Cover Remove insulating foam from refrigerant line pass- through hole as needed to gain clearance for fan plug. CONVECTION COOLING Remove internal shelving. This unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, Remove rear shelf clips, fronts can remain.
Page 50
USER GUIDE u-line.com 14. Remove and replace fan. Take special care to properly route fan wire. NOTICE Fan must be oriented to pull air in through lower evaporator cover vents and push air out at fan mounting location. 15. Installation is the reverse of removal.
Page 51
For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.
Need help?
Do you have a question about the UHDE215 and is the answer not in the manual?
Questions and answers