Kerotest Shannon Portafuse III Operator's Manual page 57

Electrofusion processor
Table of Contents

Advertisement

Kerotest Manufacturing – SHANNON & PAF III OPERATORS MANUAL - REV 3
Code
The processor is not capable of
115
outputting the current required
to fuse this fitting.
The processor is not capable of
116
outputting the voltage required
to fuse this fitting.
Input voltage is out of range and
117
the fusion cannot start.
Frequency is out of range and
118
the fusion cannot start.
Internal processor temperature
119
is out of range.
A time of 0 seconds for the
120
fusion was entered or
calculated.
Invalid Operator ID card
121
scanned.
122
Not an operator card.
The operator card scanned does
not contain privileges for the
123
functions this machine is
capable of performing.
124
Current offset is out of spec.
Resistor ID fusion cannot be
completed because the value
125
was not decoded into a valid
fusion time.
The fitting was disconnected
130
before the specified cooling
time.
An undefined error was received
131
before the fusion time was
completed.
Problem
As long as the fitting's fusion requirements are within the
specified output range of the processor. This could be an
output cable error or a calibration error. Try cleaning the
Output Lead Ends. If the problem persists, the processor will
need to be returned for service.
Verify that the input voltage and frequency displayed on the
CONNECT FITTING screen are reasonable and within the range
specified in the Specification Table (See page 8). If the
parameters displayed differ significantly from the actual input,
then there is a processor problem and it must be returned for
service.
Allow the processor to cool before fusing again. This error can
be seen if multiple large fittings are fused one after the other.
This is more than likely a temperature measurement problem.
Verify the temperature displayed in the CONNECT FITTING
screen is reasonable and within the range specified in the
Specification Table (See page 8). If the temperature displayed
differs significantly from the actual temperature then there is a
processor problem and it must be returned for service.
Verify the system date is correct and if so, contact the agency
that issued the Operator ID card.
Contact the agency that issued the Operator ID card.
Processor must be returned for calibration. You cannot fuse if
this error is detected.
Verify the fitting and the processor support the Resistor ID
method. If so the problem is with the fitting, the output cable,
or the processor calibration. If the problem persists with
multiple fittings, The processor will have to be returned for
service.
Do not disconnect the fitting before the manufacturer's
recommended cooling time has expired.
Unit must be returned for service.
Page 55 of 60