Setting the Language

When Option 3 is highlighted, press the START button to select it. Use the UP/DOWN buttons to toggle
between all supported languages. When the desired language is displayed, press the START button to save.
English is currently the only language supported by Kerotest Electrofusion Processors.

SMART Scanner™

When Option 4 is highlighted, press the START button to select it. Use the UP/DOWN buttons to toggle
between the SMART SCANNER activation values. When the desired activation value is displayed, press the
START button to save. A value of YES enables the display and remote button functionality on the SMART
Scanner™. A value of NO disables this functionality. The SMART Scanner™ will scan a barcode with either
setting.
NOTE:
This option should be set based on the type of scanning device attached to the machine (i.e. barcode wand
or SMART Scanner™). An incorrect setting may cause unexpected intermittent errors.
NONE OF THE SETTINGS IN THE ADVANCED USER MENU SHOULD BE ADJUSTED WITHOUT SPECIFIC
INSTRUCTIONS FROM THE FACTORY OR THE FITTING MANUFACTURER.
The Advanced User Menu is accessed by holding the DOWN button when the processor is first powered up.
Keep holding the DOWN button through the INTERNAL SELF TEST screen, until you are prompted for a
passcode that must be entered before proceeding. Contact an authorized representative (see page 19) to
obtain the 4 digit passcode. The following example shows the options available in the Advanced User Menu
once the correct passcode has been entered:
Use the UP/DOWN buttons to highlight the desired option. Press the START button to access the desired
option. Press the STOP button to return to normal operation.

Short Stab Detect

Short stab detection is accomplished by tracking the lowest output current during the fusion and looking for a
rise greater than an established percentage. This option allows the operator to set the percent rise in current
above which an error will be generated.
BECAUSE THE SHORT STAB IS MEASURED INDIRECTLY THROUGH CURRENT, AUTOMATIC DETECTION OF A
PROPER ASSEMBLY TECHNIQUES ARE THE RESPONSIBILITY OF THE OPERATOR.

Advanced User Menu

ADVANCED SETTINGS
1 Short Stab Detect
2 Operator ID OFF
3 Profiles
4 Calculated Res OFF
SHORT STAB IS NOT 100% GUARANTEED.