Kerotest Shannon Portafuse III Operator's Manual page 30

Electrofusion processor
Table of Contents

Advertisement

Kerotest Manufacturing – SHANNON & PAF III OPERATORS MANUAL - REV 3
After selecting Manual Fusion Mode from the Alternate Fusion selection screen (see page 26), the following
screen will be displayed:
Enter the voltage by using the UP button and DOWN button to increment and decrement the value. As either
button is held, the numbers will continue to scroll, slowly at first and then faster as time passes. When the
desired voltage is displayed, press the START button. The following screen will be displayed and you will be
able to enter the fusion time:
Enter the total number of SECONDS to fuse using the UP button and DOWN button to increment and
decrement the current value by one (1) second. As either button is held, the numbers will continue to scroll,
slowly at first and then faster as time passes. When the desired number of seconds are displayed, press the
START button.
Once the data has been successfully entered, the Kerotest Electrofusion Processor will display a screen similar
to the following:
The VERIFY SETUP screen allows the operator a final opportunity to verify that the fusion parameters
displayed are correct and match the parameters specified by the fitting manufacturer before starting the
fusion.
ALWAYS pay close attention and verify the information on this screen is correct before pressing
START.
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
CORRECT PER THE FITTING MANUFACTURER'S RECOMMENDATIONS FOR FUSING THE ATTACHED FITTING
The processor will BEEP once per second and the text "PRESS START" on the bottom line of the display will
flash on and off.
ENTER FUSION VOLTAGE
40.0 Volts
ENTER FUSION TIME
0 sec
Temperature: +75°F
VERIFY SETUP
Manual Fusion Data
40.0V
PRESS START
UNDER THE CURRENT AMBIENT CONDITIONS.
Page 28 of 60
60 sec

Advertisement

Table of Contents
loading

Table of Contents