Kerotest Manufacturing – SHANNON & PAF III OPERATORS MANUAL - REV 3
Code
The barcode was scanned
successfully, however the
100
processor cannot decode the
information into valid fusion
parameters.
Ambient temperature is out of
101
range.
Measured resistance does not
102
match resistance identified in
the barcode.
103
Shorted Coil in Fitting.
105
Can't maintain output voltage.
The power supply was shut off
108
during the previous fusion.
Reference voltage out of
109
tolerance.
STOP pressed during previous
110
fusion.
Fusion complete with no other
111
errors.
112
Fitting disconnected.
113
The calibration date has expired.
There is no valid calibration date
114
set.
Problem

Error Codes

This is not a barcode wand error or scanning problem. Verify
that the barcode is an ISO standard 24 digit fitting barcode.
Verify the temperature displayed in the CONNECT FITTING
screen is reasonable and within the range specified in the
Specification Table (See page 8). If the temperature displayed
differs significantly from the actual temperature, then there is a
processor problem and it must be returned for service.
Check Output Lead Ends and fitting adapters for excessive wear
and/or damage. If the Output Lead Ends and fitting adapters
are in good condition, reattach the processor to the fitting and
try again. If the problem persists, there is more than likely a
calibration or output cable malfunction.
Check for a short stab or a sorted coil.
Verify the Output Lead ends are clean, the power supply is sized
correctly for the fitting you are fusing, and that the power
supply is operating correctly.
This could be anything from an improperly sized generator to
someone switching the processor off during a fusion.
Processor must be returned for calibration. You cannot fuse if
this error is detected.
Do not press the STOP button during the fusion unless in an
emergency situation.
There were no problems with this fusion.
Current drops close to 0 during the fusion. If the problem
persists there is more than likely an output cable problem and
the processor should be returned for service.
Send the processor in for calibration.
Send the processor in for calibration.
Page 54 of 60