Kerotest Manufacturing – SHANNON & PAF III OPERATORS MANUAL - REV 3
If no errors were encountered, the Kerotest Electrofusion Processor will display a screen similar to the
following:
The VERIFY SETUP screen allows the operator a final opportunity to verify that the fusion parameters
displayed are correct and match the parameters specified by the fitting manufacturer before starting the
fusion.
ALWAYS pay close attention and verify the information on this screen is correct before pressing
START.
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
CORRECT PER THE FITTING MANUFACTURER'S RECOMMENDATIONS FOR FUSING THE ATTACHED FITTING
The processor will BEEP once per second and the text "PRESS START" on the bottom line of the display will
flash on and off.
Once you have verified that all measurements and parameters are correct, press the START button to begin
the fusion.
If errors were encountered while decoding the barcode number that was manually entered, you will receive
an Error Message and will be forced to check the number and reenter it.
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION COULD
RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.
NOTE:
If Calculated Resistance is enabled and the operator receives a Warning Code 55, refer to the appropriate
section on page 42 for instructions that detail how to proceed.
See page 29 for instructions on monitoring the progress of a fusion.

Manual Data Entry

**The Barcode Fusion Method is always preferred and should be used whenever possible.
should only be used when the barcode is malfunctioning or unavailable . FOR EXPERT OPERATORS
ONLY.
Manual Data Entry Fusions require additional care and attentiveness on the part of the operator to
ensure that the appropriate fusion parameters are entered. For this reason, Manual Fusions should ONLY be
performed by a fully trained operator using specifications provided by the fitting manufacturer.
NOTE:
The Kerotest Electrofusion Processor provides outputs for a complete fusion based on parameters
manually entered by the operator. Remember to enter all parameters
manufacturer.
VERIFY SETUP
INNO 2" COUPL
40.0V
PRESS START
UNDER THE CURRENT AMBIENT CONDITIONS.
Page 27 of 60
60 sec
EXACTLY
Manual Mode
as specified by the fitting