A warning code will be displayed when a situation exists that (in the manufacturer's opinion) may adversely
affect the performance of the processor over time. Warning codes are designed for informational purposes
only and have no effect on the outcome of a fusion. A warning code can be displayed either before or after a
fusion and will require user acknowledgement before normal operation can resume.
IT IS STRONGLY RECOMMENDED THAT OPERATORS FAMILIARIZE THEMSELVES WITH ALL WARNING CODES
AND THEIR CAUSES AND ADHERE TO THE RECOMMENDATIONS BELOW WHEN THEY ARE RECEIVED.
Code
Description
High Average
50
Current
Resistance out
55
of range
WARNING & ERROR CODES

Warning Codes

Cause
This warning occurs if the
average output current during a
fusion exceeds the maximum
current rating of the batteries
used to power the processor.
This is a post fusion warning and
only applies to battery powered
processors.
Occurs when the measured
resistance does not match the
resistance identified in the
fitting barcode.
Only applies when Calculated
Resistance setting is turned on.
Page 53 of 60
Recommendation
Discontinue the use of the fitting that was
fused when the warning was generated.
The fusion parameters of the particular
fitting exceed the operating specifications of
the processor.
FAILURE TO HEED THIS WARNING WILL
REDUCE THE SERVICE LIFE OF THE
BATTERIES.
The operator may choose to continue and
perform a secondary Calculated Resistance
check, or they may cancel the fusion and
resolve the problem. See Error Code 102 for
possible resolutions.
USING CALCULATED RESISTANCE IS NOT
RECOMMENDED UNLESS A 4-WIRE
MEASUREMENT FAILS. SEE PAGE 34 FOR
DETAILS.