As the fusion proceeds, the following screen will be displayed:
This screen shows the number of the current fusion as well as the time remaining (In this case, 60 seconds). If
you want to see more detailed information, press and hold the UP button to display the following fusion
information screen:
AC Powered Processors
FUSION NUMBER: 01025
40.0V 15.2A
Energy:
Gen:
120.0V
This screen displays the following information:
The most recently measured voltage and current outputs of the processor.
The total energy expended during this fusion, in amp-hours (In this case 0.085 amp-hours.). This
number increases during the fusion process as energy is expended.
The present measured voltage of the generator or battery (In this case 120.0 volts and 51.0 volts).
The current generator frequency (In AC powered processors). This number should remain
relatively constant throughout the fusion.
When the fusion is complete, the following screen will be displayed:
This screen displays the following information:
The cooling time, if specified (In this case 5 minutes).
The actual amount of time that the fitting was fused (In this case 60 seconds).
Press the START button to continue.
After the fusion process has ended, the processor will prompt the operator to disconnect the Output Lead
Ends and will not recognize any other inputs until this task is complete.
FUSION NUMBER:
60 sec
0.085Ah
60.0Hz
COOLING TIME 5 min
Actual Fusion Time
60 sec
PRESS START