Kerotest Shannon Portafuse III Operator's Manual page 39

Electrofusion processor
Table of Contents

Advertisement

Kerotest Manufacturing – SHANNON & PAF III OPERATORS MANUAL - REV 3
Once the barcode has been successfully scanned, the fitting information will be shown on the display. It
could look something like this:
This should be the same data that is displayed on the screen of the processor and is an indication that
the fusion is ready to be started. At this point in time the fusion can be started by pressing and holding
the button on the SMART Scanner™ for a few seconds. As the fusion is in progress, the SMART Scanner™
display will look something like this:
At any time, you may press and hold the button to stop the fusion.
If errors are encountered during the fusion process, the SMART Scanner™ will alert the operator by
showing the following message:
At this point, you should consult the display of the processor itself for the specific error code and take
appropriate corrective action based on the information displayed.
GPS Mode
Operating the SMART Scanner™ in GPS Mode is the same as operating the SMART Scanner™ in Smart
Scan Mode with the addition of GPS data. For this reason, only the differences are highlighted in this
section.
When the SMART Scanner™ prompts the operator to connect the fitting, the current GPS position will be
displayed after the satellites have been acquired. The screen will look something like this:
The display shows the current latitude and longitude as well as the number of satellites that the SMART
Scanner™ is currently tracking and the Position Error Indicator. The SMART Scanner™ can only
accurately report the current position when it is tracking more than 5 satellites. The example above
shows that it is tracking 8 satellites, the level of signal confidence is 1 and the current position is
39.65678 degrees North latitude and 75.77673 degrees West longitude. In general, the higher the
number of satellites and the lower the Position Error Indicator Number, the better the position accuracy
will be.
INNO 2" COUPL
60 sec START?
FUSION IN PROCESS
Press Button to STOP
ERROR RECEIVED
Check Processor!
CONNECT FITTING
39.65678N-75.77673W
Page 37 of 60
8-1

Advertisement

Table of Contents
loading

Table of Contents