Kerotest Shannon Portafuse III Operator's Manual page 45

Electrofusion processor
Table of Contents

Advertisement

Kerotest Manufacturing – SHANNON & PAF III OPERATORS MANUAL - REV 3
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
CORRECT PER THE FITTING MANUFACTURER'S RECOMMENDATIONS FOR FUSING THE ATTACHED FITTING
If you press the START button to begin a fusion and receive Warning Code 55 (see page 53 for Error & Warning
Code Definitions), the processor will display a screen similar to the following:
Press the START button to clear the warning code. The processor will display a screen similar to the following:
At this time, the operator has two options:
1.
Cancel the fusion.
2.
Perform the secondary check and attempt to continue fusing the fitting.
To CANCEL THE FUSION:
1.
Press the STOP button to cancel the fusion now. The processor will display a screen similar to the
following:
2.
Press and hold the START button to clear the error code. Follow the prompts on the processor
display. See page 54 for information how to troubleshoot an Error Code 102.
UNDER THE CURRENT AMBIENT CONDITIONS.
WARNING 55
Resistance 16.578
Min:1.21
Hold START to clear
4 wire res. is out
of range. Ignore and
do secondary check?
START=Yes
ERROR 102 RECEIVED
Resistance 16.578
Min:1.21
Hold START to clear
Page 43 of 60
RECEIVED
Max:1.78
STOP=No
Max:1.78

Advertisement