Electrofusion processor
Table of Contents

Advertisement

Kerotest Manufacturing – SHANNON & PAF III OPERATORS MANUAL - REV 3
To PERFORM SECONDARY CHECK:
1.
Press the START button to begin a Calculated Resistance check and attempt to continue the fusion.
The processor will begin the fusion process and display a screen similar following:
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION
COULD RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.
2.
If the Calculated Resistance check is successful, the fusion will proceed normally. When the fusion
is complete, a screen similar to the following will be displayed:
Press the START button to continue.
3.
If the Calculated Resistance check fails, the processor will display a screen similar to the following:
Press and hold the START button to clear the error code. Follow the prompts on the processor display. See
page 54 for information how to troubleshoot an Error Code 102.
FUSION NUMBER:
60 sec
COOLING TIME: 5 min
Actual Fusion Time
60 sec
PRESS START
ERROR 102 RECEIVED
Resistance 16.578
Min:1.21
Hold START to clear
Page 44 of 60
0125
Max:1.78

Advertisement