5.System Maintenance

@Remote

Menu
Supply Alarm
Toner
Toner Call Timing
SC/Alarm
SC Call
Setting
User Call
Comm. Test Call
Machine Info Notice
Supply Auto
Ordering Call
Machine No.
ID2 Code Display
Setting
Remote
CE call
Service
Function Flag
Communication Test
RCG Reg. State
GW URL
Polling Interval
HTTP Con Timeout
HTTP Sen Timeout
HTTP Rec Timeout
HTTP Retry Interval
HTTP Retry #
166
Sets the toner supply alarm.
[Disable / Enable]
[At rplcment / At NearEnd]
Sets the SC call.
[Disable / Enable]
Sets the user call.
[Disable / Enable]
Sets the communication test call.
[Disable / Enable]
Sets the machine information notice.
[Disable / Enable]
Sets the supply auto ordering call.
[Disable / Enable]
Displays the ID2 code (ASCII 17digits).
Performs the CE Call at the start or end of the service. [OK
/Back]
Enables or disables the remote service function.
[Disable / Enable]
Executes the communication test. [OK /Back]
Displays the RCG registration status.
[0 to 2 / 0 / 1/step]
Displays the URL for RCG center.
Sets the polling interval.
[0 to 4294967295 / 60 / 1 sec/step]
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 30 / 1 sec/step]
Specifies the send timeout interval when calling the RCG.
[0 to 100 / 30 / 1 sec/step]
Specifies the receive timeout interval when calling the RCG.
[0 to 100 / 30 / 1 sec/step]
If the HTTP connection fails, specify the interval at which the
connection will be retried again.[0 to 65535 / 3 / 1 sec/step]
If the HTTP connection fails, specify the number of times to
retry the connection.
[0 to 255 / 3 / 3 counts/step]