5.System Maintenance
Menu
Number of time to
press
Period for TEL to FAX
TX Settings
Redial Interval
Redialings
Overseas
Overseas Comm
Comm Mode
Mode
Settings
Minimum Time
Length
Dial Pulse
Dial Pulse Type
Setting
Tone Signal
Tone Signal
Settings
Transmission Time
Length
Minimum Pause in
Tone Dial
Attenuator For
Pseudo RingBack
tone To the Line
DTMF Level
DTMF Delta
162
[1 to 3 / 2 / 1step]
[Limitless / 10 sec / 20 sec/ 30 sec/ 40 sec]
Sets the redial interval when Tx fails.
[5 Min / 6 Min]
Sets the number of redials when Tx fails.
[2 times / 3 Times / 4 Times / 5 Times]
This sets the machine to ignore a DIS signal sent from the
called station once in a sending operation.
[Off / Ignore DIS Once]
If this setting is set to "On", the machine detects the CNG
signal after the line is connected. If it is set to "Off", the
machine detects the CNG signal as long as the line is
connected.
[100 Ms / 200 Ms / 300 Ms / 400 Ms]
This sets the number of pulses that are generated during
dialing.
N: Dialing '0' generates 10 pulses --- Dialing '9'
generates 9 pulses.
N+1: Dialing '0' generates 1 pulses --- Dialing '9'
generates 10 pulses.
10-N: Dialing '0' generates 10 pulses --- Dialing '9'
generates 1 pulse.
Sets the tone signal transmission time length.
[100 ms (Default)]
Sets the minimum pause during tone dialing.
[100 ms / 150 ms / 200 ms]
Sets the attenuator for pseudo ringback tone to the line.
[0 to 15 / 10 / 1 dB/step]
Sets the transmission level of DTMF tones.
[-12 dBu / -11 dBu / -10 dBu / -8 dBu / -6 dBu]
Sets the level difference between high band frequency
signals and low band frequency signals when sending
DTMF tones.
[2 dBu / 3 dBu]
Description