Menu
Comm. Test Call
Machine Info Notice
Supply Auto
Ordering Call
Machine No.
ID2 Code Display
Setting
Remote
CE call
Service
Function Flag
Communication Test
RCG Reg. State
GW URL
Polling Interval
HTTP Con Timeout
HTTP Sen Timeout
HTTP Rec Timeout
HTTP Retry Interval
HTTP Retry #
HTTP Con Delay
Max Multipart
Rescue G/W URL
Per Notice Mode
142
[Disable/ Enable]
Sets the communication test call.
[Disable/ Enable]
Sets the machine information notice.
[Disable/ Enable]
Sets the supply auto ordering call.
[Disable/ Enable]
Displays the ID2 code (ASCII 17digits).
Performs the CE Call at the start or end of the service. [OK
/Back]
Enables or disables the remote service function.
[Disable/ Enable]
Executes the communication test. [OK /Back]
Displays the RCG registration status.
[0 to 2 / 0 / 1/step]
Displays the URL for RCG center.
Sets the polling interval.
[0 to 4294967295 / 60 / 1 sec/step]
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 30 / 1 sec/step]
Specifies the send timeout interval when calling the RCG.
[0 to 100 / 30 / 1 sec/step]
Specifies the receive timeout interval when calling the RCG.
[0 to 100 / 30 / 1 sec/step]
If the HTTP connection fails, specify the interval at which the
connection will be retried again.[0 to 65535 / 3 / 1 sec/step]
If the HTTP connection fails, specify the number of times to
retry the connection.
[0 to 255 / 3 / 3 counts/step]
Specifies the connection request sending delay.
[0 to 255 / 5 / 1 sec/step]
Specifies the maximum number of multipart.
[0 to 10 / 10 / 1/step]
Displays the rescue URL.
Sets the periodic notification mode.
[0 to 5 / 0 / 1/step]