Diagnostic System; Enter Diagnostic Mode; Scroll Through The Tests - Electrolux EID200QSW00 Technical & Service Manual

Urban living dryer
Table of Contents

Advertisement

10. Diagnostic System

This information is intended for Qualified Technicians only.
CAUTION
Disconnect Electric Current Before Servicing.

10.1 Enter Diagnostic Mode

To enter Diagnostic mode, follow the instructions mentioned below:
Press power on.
Press chime and start simultaneously, hold until unit goes into diagnostics.
Press and release the normal to go to the next test.
Press mixed load to go backwards.
Tests 8.9. and 10 will give you error codes.

10.2 Scroll Through the Tests

To scroll through the tests, follow the instructions mentioned below:
Test numbers are briefly displayed when each test is selected. The test numbers also correspond to the
selector LEDs numbered from 1 at the top going down.
Test No
00
01
Condensation pump
Counter Clockwise Drum
02
Clockwise Drum rotation
03
Clockwise Drum rotation
04
NTC temp display C
Heater energizes
05
Drum rotates clockwise
NTC temp display C
Test Name
LED Test
Float and
rotation
o
o
Purpose of Test
To test the LED lights in the
User interface
Verify float switch
and water level in sump
To test the rotation of the drum in a
counter clockwise motion
To test the rotation of the drum in a
clockwise motion
Verify exhaust air
exiting unit
To test the thermistor is working
properly, sensing temperature
40
Test Results
All lights should flash
Displays
Displays
"Empty tank"
"000"
if no water is
if water is
present
present
Visual Confirmation
Visual Confirmation
The Display should read
- - C
o
The Display should read
- - C
o

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents