0x92: User Interface Protocol Incongruence Error
0x92
Main Board incompatible with User Interface Board.
0x93: Machine Configuration Checksum Error
0x93
Wrong configuration data loaded or User Interface Board defective or Main Board
or Wiring defective.
0x94: Cycle Configuration Checksum Error
0x94
Wrong configuration data loaded or Main Board defective.
0x97: Missing Program on CTF Error
0x97
Discrepancy between programme configuration data and selector recognition
data.
Checks to perform:
Check if correct User Interface Board and Main Board are installed. If not then replace the respective board
and repeat the diagnostic cycle to check for any further errors. Incorrect configuration possible.
0x9C: User Interface Configuration Checksum Error
0x9C
Discrepancy between programme configuration data and selector recognition
data.
Checks to perform:
Check if correct User Interface Board and Main Board are installed. If not then replace the respective board
0x9E: User Interface Touch Sensor Not Working
0x9E
Humidity or Water on User Interface Board or User Interface Board defective.
Checks to perform:
Switch OFF the Dryer and check for water or humidity on User Interface Board, dry it and switch it ON again
then check whether problem is solved or not, if not then replace the User Interface Board and repeat the
Troubleshooting Based on Error Codes
and repeat the diagnostic cycle to check for any further errors.
diagnostic cycle to check for any further errors.
WARNING
Check that all the connectors are correctly
inserted.
WARNING
Check that all the connectors are correctly
inserted.
WARNING
Check that all the connectors are correctly
inserted.
55
0x92
0x93
0x94
0x97
0x9C
0x9E