Electrolux EIED55HIW - 8.0 cu. Ft. Electric Dryer Wiring Diagram
Electrolux EIED55HIW - 8.0 cu. Ft. Electric Dryer Wiring Diagram

Electrolux EIED55HIW - 8.0 cu. Ft. Electric Dryer Wiring Diagram

Wiring diagram (all languages)
Hide thumbs Also See for EIED55HIW - 8.0 cu. Ft. Electric Dryer:

Advertisement

Available languages

Available languages

CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING
Please Return This Sheet to its Envelope in the Product for Future Reference
Acronym Table
CW – Clockwise
CCW – Counter Clockwise
READING ERROR CODES
1. Wake the dryer up by pressing any button but "cancel".
2. Press and hold the "cancel" and "start pause" buttons simultaneously for 6 seconds to show the last error
code recorded. The error code will appear in the display as an E followed by two numbers. NOTE: E00
means no failure code experienced.
3. To view the last 5 error codes recorded, refer to the Diagnostic Mode listed below.
4. Troubleshoot problem by using the chart below.
Error
Code
Fault
Contact Sensor
E31
frequency too high
foreign object interfering with contact
Contact Sensor
E32
frequency too low
foreign object interfering with contact
Door Sensing
E42
failure
Motor Relay failure
E51
Motor Fault –
E52
motor stopped or
not starting
Motor Centripetal
E53
Switch Failure
Motor Sensing
E54
failure
Heater Relay
E61
failure
Heater to Earth
E63
Ground
Heater Open
E64
Circuit
High Limit
Thermostat defective or Inlet Thermal
Thermostat trip
E65
count too high
Thermal Limiter
E66
Open Circuit
Heaters Sensing
E67
Failure
Dryer Tech Data Sheet
This information is intended for Qualified Technicians Only.
Contents
Error code explanation.............................................1
Error Code Chart....................................................1-2
Diagnostics .................................................................3
Français......................................................4-6
Español..............................................................7-9
Wiring Diagram.................................................10-11
Possible Fault Conditions
Electronic Control Board defective or
sensor
Electronic Control Board defective or
sensor
Electronic Control Board defective
Motor Relay stuck open or closed;
Wiring defective
Motor overheating; Laundry load too
heavy; Low power supply; Motor, or
Wiring defective
Motor Centripetal Switch, Electronic
Control Board Defective, or wiring
defective.
Electronic Control Board defective
Heater relay stuck open or closed;
Wiring defective
Heating element or wiring defective
Heating element or wiring defective
High vent restriction, High Limit
Limiter tripped (Electric Model only)
Outlet Thermal Limiter tripped Inlet
Thermal Limiter tripped (Gas
Model only) or wiring defective
Electronic Control Board defective
Possible Solutions
Check Contact Sensor and wiring. If no problems are found with Contact
Sensor, replace Electronic Control Board.
Check Contact Sensor and wiring. If no problems are found with Contact
Sensor, replace Electronic Control Board.
Replace Electronic Control Board.
If motor runs continuously with power applied check for short circuit across
motor relay (RL2), or L1 applied to motor relay output (J3-1) with cycle
stopped. If motor does not start when "start" key is pressed, check for open
circuit between L1 and motor relay connection (J3-2). If no wiring problems
found, replace Electronic Control Board.
Remove any load from dryer and check if drum turns freely by hand. Check
L1 power supply voltage, motor wiring, and motor thermal protector (if motor
thermal protector has tripped, it may take up to 30 minutes to reset).
Check wiring. Check if Motor Centripetal Switches are stuck in open or closed
positions. Replace motor. Replace Electronic Control Board.
Replace Electronic Control Board and retest.
Check for short circuit across heater relay(s) (RL5, RL6, RL7) or L1 applied
to heater relay output(s) (J5-2, J7-1, J7-3) with cycle stopped. Check for
open circuit between L1 and heater relay connection(s) (J5-1, J5-3, J7-2). If
no wiring problems are found, replace Electronic Control Board and retest.
Check heater coils and connections for short circuits to the cabinet. Replace
heater and/or wiring and retest.
Check heater coils and connections for open circuits. Replace heater and/or
For Electric Model, check Inlet Thermal Limiter for continuity. If Thermal Limiter
is open, check for evidence of high temperature event and any resulting
damage. If no further damage is evident, replace Thermal Limiter. If no
problems are found with the Thermal Limiter, check exhaust vent system for
air blockages. If no problems with vent restrictions, check/replace High Limit
Thermostat, and retest.
Check Outlet Thermal Limiter for continuity. For Gas Model, also check Inlet
Thermal Limiter for continuity. If Thermal Limiter is open, check for evidence
of high temperature event and any resulting damage. If no further
damage is evident, replace Thermal Limiter and retest.
Replace Electronic Control Board and retest.
1
Page
wiring and retest.
137032700B (0209)

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux EIED55HIW - 8.0 cu. Ft. Electric Dryer

  • Page 1: Error Codes

    Dryer Tech Data Sheet This information is intended for Qualified Technicians Only. CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING Please Return This Sheet to its Envelope in the Product for Future Reference Contents Page Error code explanation..........1 Error Code Chart............1-2 Diagnostics ..............3 Français…………………………………………..4-6 Español…………………………………………....7-9 Wiring Diagram……………………………………..10-11...
  • Page 2: Factory Reset

    Error Possible Fault Conditions Possible Solutions Fault Code Outlet Control Outlet Control Thermistor or wiring Check resistance of Outlet Control Thermistor, and check wiring for open circuit. Thermistor open defective Resistance should be between 4.9K Ohm and 6.2K Ohm at room temperature circuit (68-77°...
  • Page 3 Diagnostic Mode Selector Test/Activated Component Operator Check LCD row LCD digits Position Electric Lights / Buttons test Check Motor function. Look for Drum Motor Clockwise (CW) “MOTOR CW” rotation in clockwise direction “1111” if Contact Sensor Check moisture reading. Place fingers open circuit;”8888"...
  • Page 4 Fiche de données techniques de sécheuse Informations réservées aux techniciens qualifiés. ATTENTION : DÉBRANCHEZ L’ALIMENTATION ÉLECTRIQUE AVANT D’EFFECTUER TOUT ENTRETIEN Replacez cette fiche dans son enveloppe dans l’appareil pour référence ultérieure Tableau des acronymes SH - Sens horaire SAH - Sens antihoraire LECTURE DES CODES D’ERREUR 1.
  • Page 5 Code d’erreur Anomalie États d’anomalie Solutions Limiteur thermique avec Déclenchement du limiteur Vérifiez la continuité du limiteur thermique de sortie. Pour le modèle au thermique de sortie, du limiteur indication de gaz, vérifiez aussi la continuité du limiteur thermique d’entrée. Si le limiteur thermique d’entrée (modèle au gaz circuit ouvert thermique est ouvert, vérifiez s’il existe des indices de dommages résultant...
  • Page 6: Mode Diagnostic

    RÉINITIALISATION À L’USINE 1. Appuyez et maintenez simultanément appuyées les touches “Temperature (Température)”” et “Dryness (Degré de séchage) “ pendant 6 secondes. CYCLE D’INSTALLATION 1. Utilisez le sélecteur pour sélectionner le cycle “touch up (retouchage)” 2. Appuyez et maintenez simultanément appuyées les touches “my favorite” et “sanitize” pendant 6 secondes. 3.
  • Page 7 Hoja técnica de secadora Esta información está destinada exclusivamente a los técnicos calificados. PRECAUCIÓN: DESCONECTE LA CORRIENTE ELÉCTRICA ANTES DE DAR MANTENIMIENTO O SERVICIO Por favor devuelva esta hoja a su sobre en el producto para referencia futura Tabla de acrónimos SH - Sentido horario SCH - Sentido anti-horario LECTURA DE CÓDIGOS DE ERROR...
  • Page 8 Código error Falla Posible Condiciones de falla Soluciones posibles Circuito de limitador Compruebe la continuidad del limitador térmico de salida. Para el modelo Limitador térmico de salida desactivado de gas, compruebe además la continuidad del limitador térmico de térmico abierto limitador térmico de entrada desactivado entrada.
  • Page 9: Modo De Diagnóstico

    RECUPERAR LA CONFIGURACIÓN DE FÁBRICA 1. Mantenga presionados los botones “Temperature” y”Dryness” simultáneamente por 6 segundos. CICLO DE INSTALACIÓN 1. Use la perilla para seleccionar el ciclo de “touch up” Mantenga presionados los botones “my favorite” y “sanitize” simultáneamente por 6 segundos. 3.
  • Page 12 137032700...

Table of Contents