Electrical System Requirements - Electrolux EWED65HSS Installation Instructions Manual

Front-load gas & electric dryer
Hide thumbs Also See for EWED65HSS:
Table of Contents

Advertisement

Installation Requirements
Electrical system requirements
=
NOTE
Because of potentially Inconsistent voltage capabilities, the use of tnis dryerwith power created
by gas powered generators, solar powered generators, wind pawered generators or any other
generator other than the local utility company Is not recommended.
Electrical requirements for electric dryer:
CIRCUIT
- Individual 30 amp. branch reult
fused with 30 amp. time delay fuses or circult
breakers. Use separately fused circuits for
washer and dryer. DO NOT operate a washer
and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 240 volt,
single phase, 60 Hz, Alternating Current.
ЕЛ IMPORTANT
This dryer Is Intermally grounded to neutral unless It
was manufactured for sale In Canada. Grounding
through the neutral link Is prohibited Tor: (1) new
branch circuit Installations, (2) moble homes, (3)
recreational vehicles, and (4) areas where local
codes do not permit grounding through the neutral.
ЗМНЕ POWER SUPPLY GORD KIT (not supplied)
]^
3-wire receptacle
o>
(NEMA type 10-30R)
The dryer MUST employ a 3-conductor power
supply cord NEMA 10-30 type SRDT rated at
240 volt AC minimum, 30 amp, with 3 open
end spade lug connectors with uptumed ends
or closed loop connectors and marked for use
Electrical requirements for gas dryer:
CIRCUIT - Individual, property polartzed and
grounded 15 amp. branch circuit fused with 15
атр. time delay Tuse or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120 volt,
single phase, 60 Hz, Alternating Current.
POWER SUPPLY CORD - The dryer Is equipped
with a 120 volt 3-wire power cord.
GROUNDING
CONNECTION
- Sas "Grounding
requirements" In Electrical Installation section.
with clothes dryers. For 3-wire cord connection
Instructions sae ELECTRICAL CONNECTIONS
FOR A S-VIRE SYSTEM.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
,
4wire receptacle
| (NEMA type 14-30R)
The dryer MUST employ a 4-conductor power
supply cord NEMA 14-30 type SRDT or ST (as
required) rated at 240 volt AC minimum, 30 amp,
with 4 open end spade lug connectors with
uplumed ends or closed loop connectors and
marked tor use with clothes dryers. For 4-wire
cord connection Instructions see ELECTRICAL
CONNECTIONS
FOR A 4-WIRE SYSTEM.
=
NOTE
Dryers manufactured for sale In Canada have
factory-Installed, 4-wire power supply card
(NEMA 14-30R).
OUTLET RECEPTAGLE - NEMA 10-307 or NEMA
14-30R receptacle to be located so the power
supply cord Is accessible when the dryer E In the
Installad position.
GROUNDING CONNECTION
- Saa "Grounding
requirements" In Electrical Installation section.

Advertisement

Table of Contents
loading