Fs Spark Ignition Generator; Regular Maintenance; Replacement Ceramics - Valor Inspire 1000FS Installer And Owner Manual

Table of Contents

Advertisement

Spark ignition generator (FS only)
The spark ignition generator are battery powered (1.5-Volt).
To replace the single 'AA' battery required it is not necessary
to remove the visual baffle but you may do so if easier
access required. At the front of the electronic spark generator
there is a removable circular battery cover. Unscrew the
cover in an anticlockwise direction.
Remove any protective film from the new battery if applicable
and place into the generator. The negative (-) terminal should
go in first. The battery is marked with (+). Screw back on the
cap.

Regular maintenance.

In order to achieve and maintain high levels of personal safety and performance
efficiency, it is essential that the opening at the back of the fire and the flue are kept
clear of any form of obstruction.
It is possible that deposits of mortar or soot could fall and accumulate causing the flue
to be blocked or restricted and so preventing proper clearance of dangerous exhaust
fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant's premises checked for safety at least
every twelve months by a competent person (GAS SAFE REGISTER operative).
We recommend that all gas appliances and their flues, wherever situated, are
checked annually.
The service engineer must complete the relevant Service Record on Page 62 after
each service.
Replacement ceramics / liners / ember wool.
If you wish to replace the ceramic log fuel effect / liners / ember wool, etc spare parts
are available from our customer service team call the UK Helpline on 0844 879 35 88
or from the Republic of Ireland on 01 842 8222.
©
Page 57
GDC Group Ltd. NOV 2017