Do ensure all combustable materials must be removed from the area shown in below
diagram. The use of heat resistant plaster or board is recomended within the below
shaded areas
100
Do ensure that a combustable shelf must be a minimum of 400mm above the top of
the appliance. This is based on a 150mm deep shelf. For every extra 13mm of depth
add 25mm above the 400mm from the top of the appliance, not the trim.
Don't hang clothing, towels or any other fabrics over the fire.
Don't add any ceramic fuel effect pieces to the burner. This could cause incomplete
combustion and safety hazard.
Don't put paper or any other material on the fire.
Don't place any combustible material (rugs, carpet, plastic tiles, etc.) on the hearth.
Don't attempt to clean or service the fire until it has been switched off and allowed to
cool completely.
©
GDC Group Ltd. NOV 2017
OWNER GUIDE
X (MIN)
Page 49
Model
600FS / 600RC
800FS / 800RC
1000FS / 1000RC
Dimension X
600 mm Min
800 mm Min
922 mm Min