Installation Options - Valor Inspire 1000FS Installer And Owner Manual

Table of Contents

Advertisement

5.10 Installation options.

In the United Kingdom, as supplied, the appliance can be installed in the following
situations:
Dimension
A
B
C
D (Edge Trim)
D (Grande Trim)
E
5.10.1 Conventional fireplace and hearth.-
To a fireplace opening and hearth complying with BS1251 after removal of the
fireback and sufficient material behind the fireback for a debris catchment space.
5.10.2. 'Hole-in-the-wall' Installations
It is recommended that a hearth should be installed as in section 5.8.
-
If a hearth is not fitted, the fire must be installed so that the distance from the base
-
of the fireplace opening in the wall to the finished floor level is at least 110mm. Where
there is no floor covering or carpet and the floor is of a type that is likely to be
covered in such a way in the future then the distance from the base of the fireplace
opening in the wall to the floor level should be increased to at least 180mm.
©
GDC Group Ltd. NOV 2017
INSTALLER GUIDE
Hearth & Fireplace opening dims
600FS / 600RC
460 mm Max / 450 mm Min
635 mm Max / 600 mm Min
340 mm Min
5 mm Min
28 mm Min
300 mm Min
Note: "D" dimension critical for clearance of the trim depth
A
E
800FS / 800RC
460 mm Max / 450 mm Min
835 mm Max / 800 mm Min
340 mm Min
5 mm Min
28 mm Min
300 mm min
Page 16
B
C
D
1000FS / 1000RC
460 mm Max / 450 mm Min
957 mm Max / 922 mm Min
340 mm Min
5 mm Min
28 mm Min
300 mm min
50