Setting The Value For Gain And Deadband - Leica iCON grade iCP42 User Manual

Table of Contents

Advertisement

3.8
Adjust the gain and
deadband
Deadband
iCON grade iCP42, Operation

Setting the Value for Gain and Deadband

To adjust the gain and deadband of each of the sensors complete the following steps:
1. Press the left or right
adjust menu.
Note that it's only the current selected sensor in either left or right side that is
adjusted.
2. Use the
or
key to scroll through the settings.
3. Use the
or
4. To exit the adjust menu press the menu key.
The deadband controls the precise motion of machine hydraulics. These values do not corre-
spond to accuracy but only to hydraulic speeds. These values should not be confused with
overall machine performance and/or precision.
The automatic hydraulic calibration will set the dead band values, and these should NOT be
changed.
Default values:
Sensor
GPS
Laser
Cross slope
Tracker
Sideshift
key once, and then press the Adjust function key to enter the
key to change the value.
Dozer
1.0 cm
0.7 cm
0.6 %
0.5 cm
---
Grader
1.0 cm
0.7 cm
0.3 %
0.5 cm
2.0 cm
47