HIKVISION DS-M5504HNI Series User Manual page 60

Mobile network video recorder
Hide thumbs Also See for DS-M5504HNI Series:
Table of Contents

Advertisement

In order to avoid error report caused by voltage fluctuation, no alarm will be triggered by voltage ranging from
5VDC to 6VDC.
3.
Click the Set button of Trig Record Channel to select the alarm triggered recording channel(s). The selected channel(s)
will start to record when a connected alarm input occurs.
4.
Click the Set button of Schedule to set the arming schedule for alarm inputs. Up to 8 time periods can be set within
each day. Optionally, you can click Copy to copy the current settings to other days in the week.
5.
Check the checkbox of Handle Type and click the corresponding Set button, and you can configure the alarm linkage
actions, including Pop-up Image on Monitor, Audio Warning and Trigger Alarm Output.
Pop-up Image on Monitor
When an alarm is triggered, the local monitor displays the video image from the alarming channel configured for full
screen monitoring.
Audio Warning:
Trigger an audible beep when an alarm input is detected.
Trigger Alarm Output:
Trigger an alarm output when an alarm when an alarm input is detected.
6.
Click Apply to save the new settings and click OK to exit.
Mobile Network Video Recorder User Manual
Figure 8. 4 Arming Schedule
Figure 8. 5 Alarm Linkage Action