PARTS REQUIRED:
x2
Roof panels may cause serious injury
until securely fastened.
You must square the roof by attaching one panel first. You will use the panels' long
edge as a lever to bring your roof into square. Commonly known as "racking".
BEGIN
1
Attach the 48 x 96" panel with the rough
side up (painted-grid lines side) with a 3/4"
measurement on the first rafter from back
wall (Fig A) and the panel flush at the peak
(Fig. B).
Secure panel with two 2" nails in
the corners.
Move to the opposite end. Using the long
2
edge of the panel as a lever move the panel
side-to-side until the top corner is flush
to the peak (Fig. C) and there is a 1/2"
measurement to the gable trim (Fig. D).
You may need to move your backwall to get
the 1/2" measurement. Secure panel with
two 2" nails in the corners.
ROOF PANELS
7/16 x 48 x 96"
(1,1 x 121,9 x 243,8 cm)
Two Nails
3/4" GAUGE
BLOCK
Rafter
3/4"
Fig. A
(1,9 cm)
35
x8
x1
3/4" GAUGE
BLOCK
Flush at peak.
(1,3 cm)
2" (5,1 cm)
Fig. B
Flush at peak.
Fig. C
Gable
Trim
Fig. D
1/2"