Network Interface Errors (Ni Errors); Active Alarms - ADTRAN TSU 100 User Manual

Table of Contents

Advertisement

Chapter 4. Status Menu
Since only the user's copy of performance data is cleared by the
TSU 100, the data displayed here might be different from the
data sent to the network as PRM data.

Network Interface Errors (NI ERRORS)

The NI Errors submenu displays the types of errors the Net-
work Interface (NI) detects. A blinking CSU error LED indi-
cates that network errors are detected.
The asterisk (*) above an item indicates the type of errors
detected. The error types are the following:

Active Alarms

This menu item displays a list of current alarms (Alarm List)
reported by either the base controller or any of the ports. If no
alarms are current, using this menu item displays
This display includes two lines of text. The top line is the alarm
source. The bottom line is the alarm message. See Figure 4-3 on
page 4-5. A list of alarm messages is found in Appendix D, Sys-
tem Messages on page D-1.
In addition to normal menu operation, you can also access this
menu item with the Alarm function (
one or more of the Alarm LEDs are illuminated, an alarm is
present. Pressing
4-4
CRC-6 bit errors based on the FDL. This is valid
CRC
only in ESF mode.
Bipolar violations.
BPV
XS0
Excess zeros.
FER
Framing errors.
Cancel
TSU 100 User Manual
Shift+8
returns to the previous menu item.
.
End of List
) on the keypad. If
61202052L1-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsu 100e1202052l11202052l2

Table of Contents