Menu Item
DSR
0 INHIB
INBAND
MODE
TX CLK
SOURCE
61202052L1-1
Data Set Ready. This signal indicates to the DTE
when the DCE is turned on and ready for
operations.
Choices: *Normal, Force On
*See Table 5-2 on page 5-20
The Nx interface will detect an uninterrupted
string of zeros (0s) being transmitted toward the
network. If 0s are transmitted for >1 second, the
TSU 100e will force 1s.
Choices: On, Off
The Nx56/64 port is capable of providing an
inband communications channel (for T-WATCH
Pro and SNMP) between units. This is
accomplished by using 8 kbps of the first DS0
assigned to that particular Nx/DBU port. If in 56
K mode, no data bandwidth will be used. Inband
must also be enabled at the destination port.
Choices: On, Off, On Demand
This controls the source of the clock used by the
TSU 100 to accept transmit data from the DTE.
The default is Internal. If the application requires
that the DTE device provides the clock with the
transmit data, the External setting is used.
Choices: Internal, External
TSU 100 User Manual
Chapter 5. Configuration Menu
Description
5-19