Lumina 750
End value
Adjustment/h
Ct1 - Ct8
Tt1 - Tt2
Deviation Ct.
Deviation Tt.
Control
6.4
Function key 3: Air inlet temperature
3
Ctr.
Meas
Setting of the compost/tunnel end temperature (°C/°F). The compost/tunnel
temperature control value will gradually approach this end value.
Setting of the adjustment speed of the
or °F/hour).
Readout of the measured compost temperatures of the individual sensors. A
negative value indicates that this sensor is not included in the calculation of
the average compost temperature (opposite value to the current measured
temperature). The value -9.9 or +99.9°C(14°F or 212°F) indicates that the sensor
concerned is either faulty or not connected.
Readout of the measured tunnel temperatures of the individual tunnel sensors. The
value # indicates that the sensor concerned is either faulty or not connected.
Setting of the maximum number of degrees a compost sensor may differ from the
previous average compost temperature, if it is to be included in the calculation of
the new average. The value 0 means that only non-faulty sensors are included in
the calculation.
Setting of the maximum number of degrees a compost sensor may differ from the
previous average tunnel temperature, if it is to be included in the calculation of the
new average. The value 0 means that only non-faulty sensors are included in the
calculation.
Setting of the type of compost/tunnel temperature control:
●
COMPOST: The compost/tunnel temperature control is based on the average
compost temperature.
●
TUNNEL: The compost/tunnel temperature control is based on the average
tunnel temperature.
●
COMP+TUN: The compost/tunnel temperature control is based on the average
of compost and tunnel temperature.
Readout of the current air inlet temperature control value. Each time a phase is
started the Lumina 750 will make the control value equal to the measured air inlet
temperature. The Lumina 750 calculates the air inlet temperature control value
depending on the average compost/tunnel temperature.
Readout of the measured or average air inlet temperature (°C/°F).
Compost temperature control value
Classic screens
(°C/hour
38