Appendix E: Network Protection

The following requirements for installation of CAT5 ethernet cable must be observed for correct
operation of connected equipment.
Do NOT strip off cable sheathing more than required for proper termination.
Do NOT kink or knot cable.
Do NOT crush cable with cable ties.
Do NOT splice cable.
Do NOT bend cable at right angles or make any other sharp bends.
Note: All cable bends must have a minimum 2" (50mm.) radius.
Do NOT untwist CAT5 pairs more than ½" (12mm).
Do NOT exceed maximum 6" (150mm.) from center of ferrite to T-Link Network Connector
CAT5 Ethernet Cable
To Network
Ferrite
DSC PN 10000089
Installation Instructions
IMPORTANT!
INSTALLATION of CAT-5 Ethernet Cable
To T-Link
Network
Connector
INSTALLATION of RJ-45 to RJ-45 Mounting Plate
(CE Installations Only)
Drilling Template
NOTE:
nstall the ferrite inside the control
I
panel as close to the T-Link network
connector as allowable.
6" (150 mm.) max from center of ferrite to
the network connector).
Installation:
1.
Remove the knockout located on the
top right hand side of the cabinet.
2.
Drill 2 holes in cabinet location using
the drill template and 2.5mm (3/16")
drill bit.
3.
Secure the mounting plate externally
to the cabinet using the #6 Type F,
self-tapping screws provided.
4.
Connect RJ-45 cables observing the
"Important" notice indicated above.
5.
Verify operation.