NOTE: Uplink cell backup devices send zone 99 for a low battery and a zone 97 for communication failure (no
response from poll). These will report as contact ID E370 (protection loop). let me clarify this: these are sig-
nals GENERATED by the uplink to indicate STATUS of the uplink. The central station will assume that they
were generated by the panel. Additional codes that may be sent would be for zones 81-86 which correspond
to hardwire inputs 1-6. The contact ID message for these is selected by uplink when it is programmed. So,
next time someone reports an unusual zone 97 or 99 being reported to their Central Station, Uplink may be
the culprit. Uplink's number is 1-888-987- 5465 if you need it.
371
Protection Loop Open
372
Protection Loop Short
373
FIRE TROUBLE
374
EXIT ERROR (BY USER)
375
Panic Zone Trouble
376
Hold-Up Zone Trouble
377
Swinger Trouble
378
Cross-zone Trouble
SENSOR:
380
SENSOR TRBL - GLOBAL
381
LOSS OF SUPERVISION
382
LOSS OF SUPRVSN
383
SENSOR TAMPER
384
RF LOW BATTERY
385
SMOKE HI SENS.
386
SMOKE LO SENS.
-387 INTRUSION HI SENS.
-388 INTRUSION LO SENS.
389
DET. SELF TEST FAIL
391
Sensor Watch Failure
392
Drift Comp. Error
393
Maintenance Alert
OPEN/CLOSE:
400
Open/Close
401
OPEN/CLOSE BY USER
402
Group O/C
403
AUTOMATIC OPEN/CLOSE
404
Late to O/C
405
Deferred O/C
406
CANCEL (BY USER)
407
REMOTE ARM/DISARM
408
QUICK ARM
409
KEYSWITCH OPEN/CLOSE
435
Second Person Access
436
Irregular Access
441
Armed Stay
442
Keyswitch Armed Stay
450
Exception O/C
451
Early O/C
452
Late O/C
453
Failed to Open
454
Failed to Close
455
Auto-Arm Failed
456
Partial Arm
457
Exit Error (User)
458
User on Premises
459
Recent Close
461
Wrong Code Entry
462
Legal Code Entry
463
Re-arm after Alarm
Trouble-Prot. Loop Open-#
Trouble-Prot. Loop Short-#
Trouble-Fire Loop-# (Supervision Loss, base tamper, Supervisory open)
Alarm-Exit Error-#
Trouble-PA Trouble-#
Trouble-Hold-Up Trouble-#
Trouble – Swinger Trouble-#
Trouble – Cross Zone Trouble - # (restore not applicable)
Trouble-Sensor Trouble-#
Trouble-RF Sensor Super.-#
Trouble-RPM Sensor Super.-#
Trouble-Sensor Tamper-#
Trouble-RF Sensor Battery-#
Trouble-Smoke Hi Sens.-#
Trouble-Smoke Lo Sens.-#
Trouble-Intrusion Hi Sens.-#
Trouble-Intrusion Lo Sens.-# - These codes are similar to those used
for smart smoke detectors. The idea is to report a problem developing
in the detector's operation.
Trouble-Sensor Test Fail-#
Trouble-Sensor Watch Fail-#
Trouble-Drift Comp. Error-# - Reported by Firelite panels. The panel is
not able to adjust its thresholds to balance out drift in the normal oper-
ating point of a smoke detector.
Trouble-Maintenance Alert-#
Opening/Closing E = Open, R = Close
Opening-User # / Closing-User #
Closing-Group User #
Opening-Automatic / Closing-Automatic
Opening-Late / Closing-Late
Event & Restore Not Applicable
Opening-Cancel
Opening-Remote / Closing-Remote
Event Not Applicable for opening / Closing-Quick Arm
Opening-Keyswitch / Closing-Keyswitch
ACCESS – User #
ACCESS – Irregular Access – User #
Opening-Armed Stay / Closing-Armed Stay
Opening-Keysw. Arm Stay / Opening-Keysw. Arm Stay
Opening-Exception / Closing-Exception
Opening-Early / Closing-Early-User #
Opening-Late / Closing-Late-User #
Trouble-Fail to open (Restore not applicable)
Trouble-Fail to Close (Restore not applicable)
Trouble-Auto Arm Failed (Restore not applicable)
Closing-Partial arm-User #
Closing-Exit Error-User #
Opening-User on Prem. – User #
Trouble-Recent Close – User # (Restore not applicable)
Access – Wrong Code entry (Restore not applicable)
Access-Legal Code entry – user # (Restore not applicable)
Status-Re Arm After Alarm-User # (restore not applicable)