DSC T-Link TL300 Installation Manual page 40

Network internet alarm communicator
Table of Contents

Advertisement

TEST / MISC:
601
MANUAL TEST
602
PERIODIC TEST
603
Periodic RF Xmission
604
FIRE TEST
605
Status Report To Follow
606
LISTEN-IN TO FOLLOW
607
WALK-TEST MODE
608
System Trouble Present
609
VIDEO XMTR ACTIVE
611
POINT TESTED OK
612
POINT NOT TESTED
613
Intrusion Zone Walk Tested
614
Fire Zone Walk Tested
615
Panic Zone Walk Tested
616
Service Request
EVENT LOG:
621
EVENT LOG RESET
622
EVENT LOG 50% FULL
623
EVENT LOG 90% FULL
624
EVENT LOG OVERFLOW
625
TIME/DATE RESET
626
TIME/DATE INACCURATE
627
PROGRAM MODE ENTRY
628
PROGRAM MODE EXIT
SCHEDULING:
630
Schedule Change
631
Exception Sched. Change
632
Access Schedule Change
PERSONNEL MONITORING:
641
Senior Watch Trouble
642
Latch-key Supervision
SPECIAL CODES:
651
750-789
Miscellaneous:
654
System Inactivity
900
Download Abort
901
Download Start/End
902
Download Interrupted
910
Auto-Close with Bypass
911
Bypass Closing
Other:
999
1 and 1/3 DAY NO READ LOG EVENT LOG ONLY, No report to CS. V20/lynx series or may occur in
Test-Manually Triggered (Restore Not Applicable)
Test-Periodic (Restore Not Applicable
Test-Periodic Radio (Restore Not Applicable)
Test-Fire Walk Test-User #
Test-Fire Walk Test-User #
Listen-Listen-In Active (Restore Not Applicable)
Test-Walk Test Mode-User #
Test-System Trouble Present (Restore Not Applicable)
Listen-Video Xmitter Active (Restore Not Applicable)
Test-Point Tested OK-# (Restore Not Applicable)
Test-Point Not Tested-# (Restore Not Applicable)
Test-TntrnZone Walk Test-# (Restore Not Applicable)
Test-Fire Zone Walk Test-# (Restore Not Applicable)
Test-PA Zone Walk Test (Restore Not Applicable)
Trouble-Service Request
Trouble-Event Log Reset (Restore Not Applicable)
Trouble-Event Log 50% Full (Restore Not Applicable)
Trouble-Event Log 90% Full (Restore Not Applicable)
Trouble-Event Log Overflow (Restore Not Applicable)
Trouble-Time/Date Reset-User # (Restore Not Applicable)
Trouble-Time/Date Invalid (clock not stamping to log correctly)
Trouble-Program Mode Entry (Restore Not Applicable)
Trouble-Program Mode Exit (Restore Not Applicable
Trouble-Schedule Changed (Restore Not Applicable)
Trouble-Esc. Sched. Changed (Restore Not Applicable)
Trouble-Access Sched. Changed (Restore Not Applicable)
Trouble-Senior Watch Trouble – This code is also referred to as 'up and
about'. It means that a person has not moved about their home for a
preset period of time.
Status-Latch-key Super-User # (Restore Not Applicable) Used to
report when a certain user has returned home and disarmed the alarm.
Code sent to Identify the control panel as an ADT Authorized Dealer.
These codes are used by Protection One and can be assigned any
unique non-standard Event code, which Pro 1 will be tracking. Also can
be used on custom zone types.
Trouble – System Inactivity
Remote – Download Abort (Restore not applicable)
Remote – Download Start - #
Remote – Download End - #
Remote – Download Interrupt - #
Closing – Auto Close – Bypass - #
Closing – Bypass Closing - #
Vista-50 family after a download is done where the account has been
transferred from one panel type to another. (i.e. from and XMP to a
50P, etc).
36

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-link tl250T-link tl300cf