Drive Backplane Connectors - Lenovo ThinkSystem SR950 Setup Manual

Hide thumbs Also See for ThinkSystem SR950:
Table of Contents

Advertisement

Figure 63. RAID card connectors (type 2)
Table 230. RAID card connectors (type 2)
Callout
RAID flash power module (J14) connector
1
RAID connector for drive backplane 2 or 5 (SAS only)
2

Drive backplane connectors

The following illustration shows the internal connectors on the drive backplanes.
Note: Some cable connectors have locks or latches that must be disengaged to disconnect the cable.
There are two types of drive backplane used in the server: one that controls only SAS drives and one that
controls both SAS and NVMe drives. Cable routing for drive components is different for SAS and SAS/NVMe
drives:
• SAS drive backplane connectors
• SAS/NVMe drive backplane connectors
For information about drive backplane cable routing, see "Cable routing for drives" on page 40.
SAS drive backplane connectors
Figure 64. SAS drive backplane connectors
Table 231. SAS drive backplane connectors
Callout
Drive connector for SAS drives 0, 4, 8, 12, 16, and 20
1
Drive connector for SAS drives 2, 6, 10, 14, 18, and 22
2
Drive connector for SAS drives 1, 5, 9, 13, 17, and 21
3
Callout
RAID connector for drive backplane 1 or 4 (SAS only)
3
PCI connector to storage interposer
4
Callout
Drive connector for SAS drives 3, 7, 11, 15, 19, and 23
4
SAS signal from RAID card
5
Backplane power from interposer
6
Appendix B. Component reference
291

Advertisement

Table of Contents
loading