CAUTION:
Make sure that all server power cords are disconnected from their power sources before performing
this procedure.
Before you remove a LOM adapter from slot 9:
1. Disconnect and label all cables connected to adapters in the I/O tray; then, remove the I/O tray. See
"Remove the I/O tray" on page 334.
2. Remove the riser for slot 10 to 15 (riser 2) to access the adapter connectors in the I/O tray. See "Remove
the riser for slot 10 to 15 (riser 2)" on page 359.
Complete the following steps to remove a LOM adapter from slot 9.
Watch the procedure. A video of the installation process is available:
•
YouTube
•
Youku
Figure 68. LOM adapter removal (slot 9)
Step 1.
Fully loosen the captive thumbscrew on the side of the LOM adapter that secures it to the bracket
on the I/O tray.
Step 2.
Disengage the LOM adapter from its connector on the I/O tray and lift the adapter from the I/O tray.
After you remove a LOM adapter:
If you are instructed to return the adapter, follow all packaging instructions, and use any packaging materials
for shipping that are supplied to you.
Remove a PCIe adapter from slot 10 to 15
PCIe adapters in slot 10 to 15 are in an I/O tray riser that is accessed from the rear of the server. After
removing the I/O tray and the riser for slot 10 to 15 (riser 2), open the retention latch and remove the adapter
from the riser.