Before you install a LOM adapter in slot 9, make sure that there is no filler installed in slot 9.
Important: You must remove the riser from the I/O tray before installing an adapter.
Complete the following steps to install a LOM adapter in slot 9.
Watch the procedure. A video of the installation process is available:
YouTube
Youku
Figure 73. LOM adapter installation (slot 9)
Step 1.
Attach the extension bracket to the top of the LOM adapter using two screws.
Step 2.
Align the adapter with I/O tray slot 9 and insert it; then, press the adapter into the I/O tray until the
connector is fully seated.
Step 3.
Tighten the captive thumbscrew on the side of the LOM adapter that secures it to the bracket on
the I/O tray.
If you have no other operations to perform on the I/O tray after installing a LOM adapter in slot 9:
1. Install the riser for slot 10 to 15 (riser 2). See "Install the riser for slot 10 to 15 (riser 2)" on page 365.
2. If any of the adapters in the I/O tray have internal cables, make sure that they are connected before
installing the I/O tray.
3. Install the I/O tray in the chassis and connect all cables. See "Install the I/O tray" on page 335.
Install a PCIe adapter in slot 10 to 15
PCIe adapters in slot 10 to 15 are in an I/O tray riser that is accessed from the rear of the server. With the
riser removed from the I/O tray, open the retention latch and insert the adapter in the riser; then, close the
retention latch.
S002
ThinkSystem SR950 Setup Guide
302
" on page 56 "
" on page 254