Before you remove the hard disk drive backplane:
1. Remove the front cover. See "Remove the front cover" on page 322.
2. After noting their locations, remove any hard disk drives that are installed in the upper tray. See
"Remove a hard disk drive" on page 323.
3. Remove the upper compute tray or storage tray. See "Remove a compute tray" on page 305 or
"Remove a storage tray" on page 375.
4. Turn the tray upside down.
5. Remove the fan cage. See "Remove a fan cage (upper tray)" on page 314.
Complete the following steps to remove the hard disk drive backplane:
Watch the procedure. A video of the replacement process is available:
YouTube
Youku
Step 1.
Disconnect all power and data cables on the hard disk drive backplane that go to the storage
interposer or to connectors on the system board or optional storage tray. You might find it easier to
disconnect cables from the backplane if you disconnect them from the storage interposer first,
reconnecting them to the storage interposer after removing the backplane or installing a new one.
Other cables might also need to be removed from their retaining clips or moved to the side to
remove the backplane.
Step 2.
Turn the tray right-side up.
Step 3.
Remove the hard disk drive backplane.
Figure 93. Hard disk drive backplane (upper) removal
Grasp the backplane and pull it up and out of the upper tray.
If you are not installing another hard disk drive backplane after you remove the hard disk drive backplane:
• Install the fan cage. See "Install a fan cage (upper tray)" on page 317.