SPECIFICATIONS
7.1.2 FR-F840 (400V class)
00023
Model FR-F840-
(0.75K)
SLD
0.75 1.5
Applicable motor
*1
capacity [kW]
LD
0.75 1.5
Rated
SLD
1.8
capacity
LD
1.6
*2
[kVA]
SLD
2.3
Rated current
[A]
LD
2.1
Overload
SLD
110% of rated motor capacity for 60s, 120% of rated motor capacity for 3s (max. surrounding air temperature 40°C)
current rating
LD
120% of rated motor capacity for 60s, 150% of rated motor capacity for 3s (max. surrounding air temperature 50°C)
*3
*4
Three-phase 380 to 500V
Rated voltage
Rated input AC voltage/frequency Three-phase 380 to 500V 50Hz/60Hz
Permissible AC voltage
323 to 550V 50Hz/60Hz
fluctuation
Permissible frequency fluctuation ±5%
Without
SLD
3.2
DC
Rated input
LD
3
reactor
current
*5
SLD
2.3
[A]
With DC
reactor
LD
2.1
Without
SLD
2.5
DC
Power supply
LD
2.3
reactor
capacity
*6
SLD
1.8
[kVA]
With DC
reactor
LD
1.6
*7
IP20
Protective structure (IEC 60529)
Cooling system
Self-cooling
Weight [kg]
2.5
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 440V.
*3
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time
for the inverter and motor to return to or below the temperatures under 100% load.
*4
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However,
the maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about √2.
*5
The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and
cables) affects the rated input current.
*6
The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input
reactor and cables).
*7
FR-DU08: IP40 (except for the PU connector section)
*8
For the power voltage exceeding 480V, set Pr. 977 "Input voltage mode selection". (For details, refer to the FR-F800 Instruction Manual.)
48
00038
00052
00083
00126
00170
00250
00310
(1.5K)
(2.2K)
(3.7K)
(5.5K)
(7.5K)
(11K)
(15K)
2.2
3.7
5.5
7.5
11
15
2.2
3.7
5.5
7.5
11
15
2.9
4
6.3
10
13
19
24
2.7
3.7
5.8
8.8
12
18
22
3.8
5.2
8.3
12.6 17
25
31
3.5
4.8
7.6
11.5 16
23
29
*8
5.4
7.8
10.9 16.4 22.5 31.7 40.3 48.2 58.4 76.8 97.6 115 141 —
4.9
7.3
10.1 15.1 22.3 31
38.2 44.9 53.9 75.1 89.7 106 130 —
3.8
5.2
8.3
12.6 17
25
31
3.5
4.8
7.6
11.5 16
23
29
4.1
5.9
8.3
12
17
24
31
3.7
5.5
7.7
12
17
24
29
2.9
4
6.3
10
13
19
24
2.7
3.7
5.8
8.8
12
18
22
Forced air cooling
2.5
2.5
3.0
3.0
6.3
6.3
8.3 8.3
00380
00470
00620
00770
00930
01160
01800
(18.5K)
(22K)
(30K)
(37K)
(45K)
(55K)
(75K)
18.5 22
30
37
45
55
75
18.5 22
30
37
45
55
75
29
36
47
59
71
88
137 165 198 248 275 329 367 417 465 521
27
33
43
53
65
81
110 137 165 198 248 275 329 367 417 465
38
47
62
77
93
116
180
35
43
57
70
85
106
144
38
47
62
77
93
116 180 216 260 325 361 432 481 547 610 683
35
43
57
70
85
106 144 180 216 260 325 361 432 481 547 610
37
44
59
74
88
107 —
34
41
57
68
81
99
29
36
47
59
71
88
137 165 198 248 275 329 367 417 465 521
27
33
43
53
65
81
110 137 165 198 248 275 329 367 417 465
IP00
15
15
23
41
41
43
02160
02600
03250
03610
04320
04810
05470
(90K)
(110K)
(132K)
(160K)
(185K)
(220K)
(250K)
110
132 160 185 220 250 280 315 355
90
110 132 160 185 220 250 280 315
216
260
325 361 432 481 547 610 683
180
216
260 325 361 432 481 547 610
52
55
71
78
117
117
166 166 166
06100
06830
(280K)
(315K)