Parameter Name
Second motor
462
constant (X)
Second motor auto
463
tuning setting/status
Remote output
495
selection
496
Remote output data 1
497
Remote output data 2
PLC function flash
498
memory clear
Stop mode selection
502
at communication
error
503
Maintenance timer 1
Maintenance timer 1
504
alarm output set time
Speed setting
505
reference
Emergency drive
*13
514
dedicated retry
waiting time
Emergency drive
*13
515
dedicated retry count
Output stop
522
frequency
Emergency drive
*13
523
mode selection
Emergency drive
*13
524
running speed
Modbus-RTU
*14
539
communication
check time interval
Frequency command
*11
541
sign selection
CC-Link extended
*11
544
setting
USB communication
547
station number
USB communication
548
check time interval
*14
549
Protocol selection
*2
For FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower
*3
For FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher
*9
Differs according to types. (FM type/CA type)
*11
The setting is available for the FR-F800-E or when a compatible plug-in option is installed.
*13
Setting available for standard models only.
*14
Not available for FR-F800-E.
Initial
Setting Range
Value
9999
0 to 100%, 9999
0
0, 1, 11, 101
0, 1, 10, 11
0
0
0 to 4095
0
0 to 4095
0, 9696
0
(0 to 9999)
0
0 to 4
0
0 (1 to 9998)
9999
0 to 9998, 9999
*9
1 to 590Hz
60/50Hz
0.1 to 600s,
9999
9999
1
1 to 200, 9999
0 to 590Hz,
9999
9999
100, 111, 112,
121, 122, 123,
124, 200, 211,
212, 221, 222,
223, 224, 300,
9999
311, 312, 321,
322, 323, 324,
400, 411, 412,
421, 422, 423,
424, 9999
0 to 590Hz/
9999
0 to 100%, 9999
0 to 999.8s,
9999
9999
0
0, 1
0, 1, 12, 14, 18,
24, 28, 100,
0
112, 114, 118,
128
0 to 31
0
0 to 999.8s,
9999
9999
0, 1, 2
0
Parameter Name
NET mode operation
550
command source
selection
PU mode operation
551
command source
selection
Frequency jump
552
range
553
PID deviation limit
PID signal operation
554
selection
555
Current average time
Data output mask
556
time
Current average
value monitor signal
557
output reference
current
Second frequency
560
search gain
PTC thermistor
561
protection level
Energization time
563
carrying-over times
Operating time
564
carrying-over times
Second motor
565
excitation current
break point
Second motor
excitation current
566
low-speed scaling
factor
Second motor speed
569
control gain
Multiple rating
570
setting
Holding time at a
571
start
4mA input check
573
selection
Second motor online
574
auto tuning
Output interruption
575
detection time
Output interruption
576
detection level
Output interruption
577
release level
BASIC OPERATION
Initial
Setting Range
Value
*11
9999
0, 1, 5
, 9999
*11
1 to 3, 5
,
9999
9999
9999
0 to 30Hz, 9999
9999
0 to 100%, 9999
0
0 to 7, 10 to 17
1s
0.1 to 1.0s
0s
0 to 20s
*2
Inverter
0 to 500A
LD/SLD
rated
*3
0 to 3600A
*9
current
0 to 32767,
9999
9999
Ω
0.5 to 30k
,
9999
9999
(0 to 65535)
0
0
(0 to 65535)
0 to 400Hz,
9999
9999
0 to 300%
9999
9999
0 to 200%, 9999
*9
0, 1
1/0
9999
0 to 10s, 9999
1 to 4, 9999
9999
0
0, 1
0 to 3600s,
1s
9999
0 to 590Hz
0Hz
1000%
900 to 1100%
35

Advertisement