Parameter Name
Digital trigger
1046
channel
Digital trigger
1047
operation selection
Display-off waiting
1048
time
1049
USB host reset
1106
Torque monitor filter
Running speed
1107
monitor filter
Excitation current
1108
monitor filter
Station number in
1124
*11
inverter-to-inverter
link
Number of inverters
1125
*11
in inverter-to-inverter
link system
Pre-charge change
1132
increment amount
Second pre-charge
1133
change increment
amount
1134
Parameter for manufacturer setting. Do not set.
1135
Second PID display
1136
bias coefficient
Second PID display
1137
bias analog value
Second PID display
1138
gain coefficient
Second PID display
1139
gain analog value
Second PID set
1140
point/deviation input
selection
Second PID
1141
measured value
input selection
Second PID unit
1142
selection
Second PID upper
1143
limit
Second PID lower
1144
limit
Second PID
1145
deviation limit
Second PID signal
1146
operation selection
Second output
1147
interruption
detection time
Second output
1148
interruption
detection level
*11
The setting is available for the FR-F800-E or when a compatible plug-in option is installed.
Initial
Setting Range
Value
1
1 to 8
0
0, 1
0 to 60min
0min
0
0, 1
9999
0 to 5s, 9999
9999
0 to 5s, 9999
9999
0 to 5s, 9999
9999
0 to 5, 9999
2
2 to 6
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 500, 9999
20%
0 to 300%
9999
0 to 500, 9999
100%
0 to 300%
2
1 to 5
1 to 5,
3
101 to 105
9999
0 to 43, 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
0.0 to 100.0%,
9999
9999
0
0 to 3, 10 to 13
0 to 3600s,
1s
9999
0Hz
0 to 590Hz
Parameter Name
Second output
1149
interruption cancel
level
1150
User parameters
to
1 to 50
1199
PID gain tuning
1211
timeout time
Step manipulated
1212
amount
Step responding
1213
sampling cycle
Timeout time after
1214
the maximum slope
Limit cycle output
1215
upper limit
Limit cycle output
1216
lower limit
Limit cycle
1217
hysteresis
PID gain tuning
1218
setting
PID gain tuning start/
1219
status
1300
to
1343
Communication option parameters
1350
to
1359
Detection time for
1361
PID output hold
PID output hold
1362
range
1363
PID priming time
Stirring time during
1364
sleep
1365
Stirring interval time
1366
Sleep boost level
Sleep boost waiting
1367
time
Output interruption
1368
cancel time
Check valve closing
1369
completion
frequency
Detection time for
1370
PID limiting
operation
PID upper/lower limit
1371
prewarning level
range
BASIC OPERATION
Initial
Setting Range
Value
1000%
900 to 1100%
0 to 65535
0
100s
1 to 9999s
1000%
900 to 1100%
1s
0.01 to 600s
10s
1 to 9999s
1100%
900 to 1100%
900 to 1100%
1000%
1%
0.1 to 10%
0, 100 to 102,
111, 112, 121,
0
122, 200 to 202,
211, 212, 221,
222
(0), 1, 8,
0
(9, 90 to 96)
5s
0 to 900s
9999
0 to 50%, 9999
9999
0 to 360s, 9999
15s
0 to 3600s
0h
0 to 1000h
9999
0 to 100%, 9999
0s
0 to 360s
0s
0 to 360s
0 to 120Hz,
9999
9999
0s
0 to 900s
9999
0 to 50%, 9999
41