Download Print this page

Mitsubishi Electric FR-F840-00023 Installation Manuallines page 48

Hide thumbs Also See for FR-F840-00023:

Advertisement

BASIC OPERATION
Parameter Name
PID measured value
1372
control set point
change amount
PID measured value
1373
control set point
change rate
Auxiliary pressure
1374
pump operation
starting level
Auxiliary pressure
1375
pump operation
stopping level
Auxiliary motor
1376
stopping level
PID input pressure
1377
selection
PID input pressure
1378
warning level
PID input pressure
1379
fault level
PID input pressure
1380
warning set point
change amount
PID input pressure
1381
fault operation
selection
Starting times lower
1410
4 digits
Starting times upper
1411
4 digits
Motor induced
1412
voltage constant
(phi f) exponent
Second motor
induced voltage
1413
constant (phi f)
exponent
Ethernet communica-
1424
*11
tion network number
Ethernet communica-
1425
*11
tion station number
Link speed and
1426
*11
duplex mode
selection
Ethernet function
1427
*11
selection 1
Ethernet function
1428
*11
selection 2
Ethernet function
1429
*11
selection 3
Ethernet signal loss
1431
*11
detection function
selection
Ethernet communi-
1432
*11
cation check time
interval
*11
The setting is available for the FR-F800-E or when a compatible plug-in option is installed.
42
Initial
Setting Range
Value
5%
0 to 50%
0%
0 to 100%
1000%
900 to 1100%
1000%
900 to 1100%
9999
0 to 100%, 9999
1, 2, 3, 9999
9999
20%
0 to 100%
9999
0 to 100%, 9999
5%
0 to 100%
0
0, 1
0
0 to 9999
0
0 to 9999
9999
0 to 2, 9999
9999
0 to 2, 9999
1
1 to 239
1 to 120
1
0
0 to 4
502,
5000 to 5002,
5006 to 5008,
5001
5010 to 5013,
9999, 45237,
61450
502,
5000 to 5002,
5006 to 5008,
45237
5010 to 5013,
9999, 45237,
61450
502,
5000 to 5002,
5006 to 5008,
9999
5010 to 5013,
9999, 45237,
61450
0
0 to 3
0 to 999.8s,
9999
9999
Parameter Name
1434
*11
Ethernet IP address 1
1435
*11
Ethernet IP address 2
1436
*11
Ethernet IP address 3
1437
*11
Ethernet IP address 4
1438
*11
Subnet mask 1
1439
*11
Subnet mask 2
1440
*11
Subnet mask 3
1441
*11
Subnet mask 4
Ethernet IP filter
1442
*11
address 1
Ethernet IP filter
1443
*11
address 2
Ethernet IP filter
1444
*11
address 3
Ethernet IP filter
1445
*11
address 4
Ethernet IP filter
1446
*11
address 2 range
specification
Ethernet IP filter
1447
*11
address 3 range
specification
Ethernet IP filter
1448
*11
address 4 range
specification
Ethernet command
1449
*11
source selection IP
address 1
Ethernet command
1450
*11
source selection IP
address 2
Ethernet command
1451
*11
source selection IP
address 3
Ethernet command
1452
*11
source selection IP
address 4
Ethernet command
source selection IP
1453
*11
address 3 range
specification
Ethernet command
source selection IP
1454
*11
address 4 range
specification
1455
*11
Keepalive time
PID multistage set
1460
point 1
PID multistage set
1461
point 2
PID multistage set
1462
point 3
PID multistage set
1463
point 4
PID multistage set
1464
point 5
PID multistage set
1465
point 6
PID multistage set
1466
point 7
Initial
Setting Range
Value
192
0 to 255
168
0 to 255
50
0 to 255
1
0 to 255
255
0 to 255
255
0 to 255
255
0 to 255
0
0 to 255
0 to 255
0
0
0 to 255
0
0 to 255
0 to 255
0
9999
0 to 255, 9999
9999
0 to 255, 9999
9999
0 to 255, 9999
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255, 9999
0
0 to 255, 9999
3600s
1 to 7200s
9999
9999
9999
9999
0 to 100%, 9999
9999
9999
9999

Advertisement

loading