Download Print this page

Mitsubishi Electric FR-F840-00023 Installation Manuallines page 45

Hide thumbs Also See for FR-F840-00023:

Advertisement

Parameter Name
Power saving
897
monitor average time
Power saving
898
cumulative monitor
clear
Operation time rate
899
(estimated value)
C0
FM/CA terminal
*9
*8
(900)
calibration
C1
AM terminal
*8
calibration
(901)
Terminal 2 frequency
C2
setting bias
*8
(902)
frequency
C3
Terminal 2 frequency
*8
setting bias
(902)
Terminal 2 frequency
125
setting gain
*8
(903)
frequency
C4
Terminal 2 frequency
*8
setting gain
(903)
Terminal 4 frequency
C5
setting bias
*8
(904)
frequency
C6
Terminal 4 frequency
*8
setting bias
(904)
Terminal 4 frequency
126
setting gain
*8
(905)
frequency
C7
Terminal 4 frequency
*8
setting gain
(905)
C12
Terminal 1 bias
*8
frequency (speed)
(917)
C13
Terminal 1 bias
*8
(speed)
(917)
C14
Terminal 1 gain
*8
frequency (speed)
(918)
C15
Terminal 1 gain
*8
(speed)
(918)
C16
Terminal 1 bias
*8
command (torque)
(919)
C17
Terminal 1 bias
*8
(torque)
(919)
*2
For FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower
*3
For FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher
*8
The parameter number in parentheses is the one for use with the LCD operation panel (FR-LU08) and the parameter unit (FR-PU07).
*9
Differs according to types. (FM type/CA type).
*10
The setting is available only with the CA type.
Initial
Setting Range
Value
0, 1 to 1000h,
9999
9999
9999
0, 1, 10, 9999
0 to 100%,
9999
9999
0Hz
0 to 590Hz
0%
0 to 300%
*9
0 to 590Hz
60/50Hz
100%
0 to 300%
0 to 590Hz
0Hz
20%
0 to 300%
*9
0 to 590Hz
60/50Hz
100%
0 to 300%
0 to 590Hz
0Hz
0%
0 to 300%
*9
0 to 590Hz
60/50Hz
100%
0 to 300%
0%
0 to 400%
0%
0 to 300%
Parameter Name
C18
Terminal 1 gain
*8
command (torque)
(920)
C19
Terminal 1 gain
*8
(torque)
(920)
C8
Current output bias
(930)
signal
*8,*10
C9
Current output bias
(930)
current
*8,*10
C10
Current output gain
(931)
signal
*8,*10
C11
Current output gain
(931)
current
*8,*10
C38
Terminal 4 bias
*8
command (torque)
(932)
C39
Terminal 4 bias
*8
(torque)
(932)
C40
Terminal 4 gain
*8
command (torque)
(933)
C41
Terminal 4 gain
*8
(torque)
(933)
C42
PID display bias
*8
coefficient
(934)
C43
PID display bias
*8
analog value
(934)
C44
PID display gain
*8
coefficient
(935)
C45
PID display gain
*8
analog value
(935)
Input voltage mode
977
selection
Parameter copy
989
alarm release
BASIC OPERATION
Initial
Setting Range
Value
150%
0 to 400%
100%
0 to 300%
0%
0 to 100%
0%
0 to 100%
100%
0 to 100%
100%
0 to 100%
0%
0 to 400%
20%
0 to 300%
150%
0 to 400%
100%
0 to 300%
0 to 500.00,
9999
9999
20%
0 to 300.0%
0 to 500.00,
9999
9999
100%
0 to 300.0%
0
0, 1
*2
*2
10
10
*3
*3
100
100
39

Advertisement

loading