Parameter Name
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
232
Multi-speed setting
to
(speeds 8 to 15)
239
Soft-PWM operation
240
selection
Analog input display
241
unit switchover
Terminal 1 added
242
compensation
amount (terminal 2)
Terminal 1 added
243
compensation
amount (terminal 4)
Cooling fan
244
operation selection
245
Rated slip
Slip compensation
246
time constant
Constant-power
247
range slip compen-
sation selection
Self power
248
management
selection
Earth fault detection
249
at start
250
Stop selection
Output phase loss
251
protection selection
252
Override bias
253
Override gain
*9
Differs according to types. (FM type/CA type)
*11
The setting is available for the FR-F800-E or when a compatible plug-in option is installed.
*13
Setting available for standard models only.
Initial
Setting Range
Value
*13
0, 1, 2
, 3 to 5,
99
7, 8, 10 to 19, 25,
26, 35, 39 to 42,
45 to 54, 57, 64,
*13
*13
65
, 66
, 67,
68, 70 to 80, 82,
*13
85
, 90, 91, 94
to 96, 98 to 101,
*13
102
, 103 to
105, 107, 108,
110 to 116, 125,
126, 135, 139 to
142, 145 to 154,
*13
157, 164, 165
,
*13
166
, 167, 168,
9999
170 to 180, 182,
*13
185
, 190, 191,
194 to 196, 198
to 208, 211 to
213, 215, 217 to
220, 226, 228 to
*11
230, 242
, 300
to 308, 311 to
313, 315, 317 to
320, 326, 328 to
*11
330, 342
,
9999
0 to 590Hz,
9999
9999
1
0, 1
0
0, 1
100%
0 to 100%
0 to 100%
75%
1
0, 1, 101 to 105
0 to 50%, 9999
9999
0.5s
0.01 to 10s
0, 9999
9999
0
0 to 2
0
0, 1
0 to 100s,
9999
1000 to 1100s,
8888, 9999
1
0, 1
50%
0 to 200%
150%
0 to 200%
Parameter Name
Main circuit power
254
OFF waiting time
255
Life alarm display
Inrush current limit
*13
256
circuit life display
Control circuit
257
capacitor life display
Main circuit
*13
258
capacitor life display
Main circuit
*13
capacitor life
259
measuring
PWM frequency
260
automatic
switchover
Power failure stop
261
selection
Subtracted
262
frequency at
deceleration start
Subtraction starting
263
frequency
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power failure decel-
266
eration time switcho-
ver frequency
Terminal 4 input
267
selection
Monitor decimal
268
digits selection
Parameter for manufacturer setting.
269
Do not set.
Inverter output
289
terminal filter
Monitor negative
290
output selection
Pulse train I/O
291
selection
UV avoidance
294
voltage gain
Frequency change
295
increment amount
setting
296
Password lock level
Password lock/
297
unlock
Frequency search
298
gain
Rotation direction
299
detection selection
at restarting
BASIC OPERATION
Initial
Setting Range
Value
1 to 3600s,
600s
9999
0
(0 to 15)
100%
(0 to 100%)
100%
(0 to 100%)
100%
(0 to 100%)
0
0, 1
1
0, 1
0 to 2, 11, 12,
0
21, 22
3Hz
0 to 20Hz
0 to 590Hz,
*9
60/50Hz
9999
5s
0 to 3600s
0 to 3600s,
9999
9999
*9
0 to 590Hz
60/50Hz
0
0 to 2
9999
0, 1, 9999
5 to 50ms, 9999
9999
0
0 to 7
0, 1, 10, 11, 20,
21, 100
0
(FM type)
0,1 (CA type)
0 to 200%
100%
0, 0.01, 0.10,
0
1.00, 10.00
0 to 6, 99, 100
9999
to 106, 199,
9999
(0 to 5),
9999
1000 to 9998,
9999
0 to 32767,
9999
9999
9999
0, 1, 9999
33