Ac Output Wiring; Figure 11, Ac Wiring Connections - Magnum Energy MM AE Series Owner's Manual

Table of Contents

Advertisement

2.0 Installation
N e u tra l
In
(w h ite)
H o t
In
(b la ck)

Figure 11, AC Wiring Connections

AC Output Wiring

CAUTION: The inverter's AC output must never be con-
nected to an AC power source. This will cause severe
damage to the inverter and is not covered under war-
ranty.
When hardwiring the output of the inverter, a cable must be routed
from the inverter's output to an AC distribution panel (sub-panel)
that provides overcurrent protection to the loads powered by the in-
verter. Connect the AC output to this distribution panel as described
below:
1. Remove the 1/2" knockout on the AC Output Connection
(see Figure 4, Item 15) – use a utility knife to cut thru the round
slot.
2. Discard this knockout and install a 1/2" strain relief in the AC OUT
opening. You may need to fi le the opening edge for proper fi t.
3. Run a 2-conductor plus ground cable through the strain relief in
the AC OUT opening. Refer to Table 4 for the minimum wire size and
the overcurrent protection required for the AC output wiring.
20
A C
G ro u n d
In /O u t
(g re e n)
Strain
reliefs
AC IN
AC O UT
N e u tra l O u t
(w h ite w/ b la ck
strip e )
H o t
O u t
(re d)
© 2010 Magnum Energy, Inc.