(8) Description of MENU 6 Functions
For operation details, refer to the ASP-80 manual.
MENU6 <SETUP(ASP-80)>
1.ZERO CARIBRATION
2.AWB(6500k)
3.AWB(9300k)
4.AWB(USER DATA)
5.MEASUREMENT & MEMORY
6.REAL TIME MEASUREMENT
NEXT →(MENU)
SELECT→(ENT) EXIT→(ESC)
① Zero calibration
Perform the calibration of ASP-80.
Connect ASP-80 to the monitor, and make sure to
perform this calibration before proceeding onwards.
The function is disabled unless ASP-80 is
connected.
Be careful not to allow external light into the
sensor.
When the sensor is not receiving light to be
measured, the message "ERROR 1 : TOO LIGHT"
appears.
② Auto white balance (6500k)
Setup at 6500k.
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.
③ Auto white balance (9300k)
Setup at 9300k.
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.
(9) Description of MENU 7 Functions
* This menu is intended to control the embedded audio module DKM-5**AV,AVD and the embedded audio level
meter module DAM-504,508.
The setting in this menu does not function for a monitor without the above modules.
MENU7 <AUDIO>
1.LINE/OUT CH
CH1/2
2.LED ENABLE
CH1 TO 8
3.LED DIMMER
HIGH
NEXT →(MENU)
SELECT→(ENT) EXIT→(ESC)
① Paired channel selection
Select the DKM-5**AV analog audio line output
(2ch) from the four pairs of channels CH1/2, CH3/
4, CH5/6 and CH7/8.
This function is disabled for the embedded digital
audio output model (DKM-5**AVD).
① Zero calibration
② Auto white balance (6500k)
③ Auto white balance (9300k)
④ Auto white balance (User data)
⑤ Color temperature/luminance measurement and memory
⑥ Real-time color temperature and luminance measurement
④ Auto white balance (User data)
⑤ Color temperature and luminance
⑥ Real-time color temperature and luminance
① Paired channel selection
② Level meter channel selection
③ Level meter brightness setting
② Level meter channel selection
③ Level meter brightness setting
37
Setup at user color temperature.
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.
measurement and memory
Measure the color temperature, luminance and
raster luminance of the user setting.
The results can be stored as USER DATA if necessary.
Measurable ranges are as follows.
Luminance :
10~190cd/ ㎡
Raster luminance :
0.01~0.99cd/ ㎡
Color temperature
0.250~0.380
(x, y coordinates) :
measurement
Color temperature and luminance are measured
for real-time display of the readings.
The function can also be applied to the measurement
of other devices.
Select the display channel of DAM-504/508 from 8-
channel (CH1 TO 8), 6-channel (CH1 TO 6) and 2-
channel (CH1 TO 2) as necessary.
For DAM-504 (4-channel model), the selections of
8-channel and 6-channel are disabled.
Select the brightness of DAM-504/508 level meter
LED from HIGH, MID, LOW and OFF.
The setting is not applied to the tally (red and green).