Installation; External Connection; Standard Module - Ikegami HTM-1990R Operation Manual

Multi-format color monitor
Hide thumbs Also See for HTM-1990R:
Table of Contents

Advertisement

3. Installation

Caution: For your safety, turn off the power of each equipment before connection.

3-1. External connection

(1) Standard module (MPU, VIDEO PROCESS)
REMOTE
SERIAL
PARALLEL
PARALLEL REMOTE signal input
• Connect the supplied remote connector here. 
• For details of pin connection, refer to 3.2. 
 
SERIAL REMOTE signal input
• Connect the BNC cable from the serial remote controller SRC-301Z here. 
• By adopting the loop through connection method, up to 99 monitors can be controlled  
  individually or together. 
• If not adopting the loop through connection method, connect the terminated plug. 
• Set the monitor ID in the MENU screen. 
 
MPU module
Option module *Refer to the pages that follow.
VIDEO PROCESS module
YPbPr/RGB A channel input
YPbPr/RGB
• Input here an RGB signal or YPbPr signal. 
CH A
• Input formats 
  ①  480i/59.94 
  ②  575i/50 
Y/G
  ③  480p/59.94 (option) 
  ④  1035i/60,59.94 
  ⑤  1080i/60,59.94 
  ⑥  1080i/50 
  ⑦  1080p/24sF8(23.98sF) (option) 
  ⑧  720p/60,59.94 
Pb/B
  ⑨  720p/50 (option) 
• Signal format 
  The signal format needs to be set at the MENU 1-2 HDTV/SDTV 
   item. For 1080i or 1035i, the MENU 1-3 1035i/1080i item also  
  needs to be set. 
• Switch YPbPr/RGB at the MENU 1-4 item. 
Pr/R
• If not adopting the loop through connection method, connect the  
  terminated plug.
SYNC
EXT SYNC signal input
• If the YPbPr/RGB signal or the DE-801 decoder module's composite  
  signal is externally synchronized, input an external sync signal here. 
• If not adopting the loop through connection method, connect the  
  terminated plug. 
 