7.7.23 Parameters in the "Device Settings / Measurement Uncertainty" Menu

Parameter
Setting Values
Active
Off*
On
Method
User input
Calibration
User input
certificate
Date
User input
Created by
User input
Accreditation
User input
Displayed value
Absolute uncertainty*
Relative uncertainty
Process accuracy
Process accuracy
Enter factor
factor
Summand a(1)
Enter summand
Factor b(1)
Enter factor
Exponent b(1) (e-)
Enter exponent
Summand a(n)
Enter summand
Factor b(n)
Enter factor
Exponent b(n) (e-)
Enter exponent
* Factory setting
7.7.24 Parameters in the "Device Settings / Device ID" Menu
Parameter
Setting Values
Device ID 1
User input
Device ID 2
User input
80
Operating Instructions Cubis
Explanation
If this extension has been activated in the QAPP Center:
Disables the measurement uncertainty.
If this extension has been activated in the QAPP Center:
Activates the dynamic display of the measurement uncertainty
for the weight value.
If this extension has been activated in the QAPP Center:
Saves a name assigned for the method, e.g., EURAMET cg-18
If this extension has been activated in the QAPP Center:
Saves a name assigned for the calibration certificate.
If this extension has been activated in the QAPP Center:
Defines the date of the measurement uncertainty.
If this extension has been activated in the QAPP Center:
Saves the name of the user.
If this extension has been activated in the QAPP Center:
Saves the name of the accreditation.
If this extension has been activated in the QAPP Center:
Calculates the measurement uncertainty as an absolute value.
If this extension has been activated in the QAPP Center:
Calculates the measurement uncertainty as a relative value.
If this extension has been activated in the QAPP Center:
Calculates the measurement uncertainty according to the input
of the process accuracy factors.
If this extension has been activated in the QAPP Center:
Saves the entry for the process accuracy factor.
If this extension has been activated in the QAPP Center:
Saves the entries for range 1.
If this extension has been activated in the QAPP Center:
Saves the entries for range n.
Explanation
Saves the entered device ID.
Saves the entered device ID.