6.11

Replacing the dispensing nozzle

Spare parts
Outlet nozzle
Baffle
Baffle seal
Concentrate baffle
Diffusor
Diffusor seal
NOTICE!
Please use gloves!
1. Unlock the outlet nozzle by turning it.
2. Pull the outlet nozzle with the baffle downwards out of the dispensing valve.
3. Remove the baffle (Fig. 43/1) and (Fig. 44/1) from the outlet nozzle (Fig. 43/2) and (Fig. 44/2).
4. Insert the new baffle (Fig. 43/1) and (Fig. 44/1) into the new outlet nozzle (Fig. 43/2) and (Fig.
44/2).
NOTICE!
The outlet nozzle is easier to insert into the dispensing valve if it is moistened with water beforehand.
Installation and service manual Dispensing valve
UFB1
22
ID/reference
1945
1917
4073
560001733
1913
311086000
Qty/amount
Comment
1
1
1
1
1
1
Fig. 42
Fig. 43 Standard dispens-
ing nozzle
Fig. 44 Juice dispensing
nozzle
Cornelius Deutschland GmbH
Document no. TD2004100
Version 15/03/2019, Index 0