7.1.3

"Incremental" configuration mode

The module stores the sums of all successive fill times of one single beverage size as one single fill time without any pauses.
During configuration, the "PGM" indicator flashes. The last successive fill times are stored as a beverage size when exiting con-
figuration mode.
If a new beverage size needs to be configured, it can be configured after another beverage size has been set, or by exiting con-
figuration mode and calling it up again.
NOTICE!
Use the actual cup sizes and amounts of ice for the configuration.
1. Call up the "Incremental" configuration mode by pressing the program button (Fig. 48/3) and
the "L" button (Fig. 48/2) simultaneously for 5 seconds.
To prevent any unintentional dispensing, press the program button (Fig. 48/3) slightly earlier
than the "L" button (Fig. 48/2).
The "PGM" indicator (Fig. 48/5) lights up.
2. Place a cup on the drip tray of the base unit and under the dispensing nozzle of the dispensing
valve.
3. Press the button (Fig. 48/1) for the beverage size to be configured until the fill level in the cup
is reached.
The "PGM" indicator (Fig. 48/5) flashes.
4. Wait until the foam has settled in the cup and press the button (Fig. 48/1) for the beverage size again until the fill level in the
cup is reached.
5. Repeat this process until the fill level in the cup is reached.
The sum of all the successive fill times is stored in the module as one single fill time with no pauses when you exit configuration
mode.
6. Repeat the process for all beverage sizes.
7. Exit configuration mode by pressing the program button (Fig. 48/3) or the "Start & Stop" button (Fig. 48/4) for 5 seconds.
The "PGM" indicator (Fig. 48/5) goes out.
The last fill time set for each beverage size is stored.
7.1.4

Restoring the factory settings

Restoring the factory settings resets the fill times of the dispensing valve to the standard fill times, see table Tab. 7-1Fill times fac-
tory setting.
1. Call up "Standard" configuration mode by pressing the program button (Fig. 49/2) for 5 sec-
onds.
The "PGM"" indicator (Fig. 49/4) lights up.
2. Press the "Start & Stop" button (Fig. 49/3) and the required button (Fig. 49/1) for the beverage
size simultaneously.
Make sure that you press the "Start & Stop" button (Fig. 49/3) and the button (Fig. 49/1) for the
beverage size at roughly the same time, so that you do not quit configuration mode.
The "PGM" indicator (Fig. 49/4) flashes.
3. Press the button (Fig. 49/1) for the beverage size to set the fill time to the factory setting.
The "PGM" indicator (Fig. 49/4) flashes.
4. Release the "Start & Stop" button (Fig. 49/3) and the button (Fig. 49/1) for the beverage size.
5. Press the "Start & Stop" button (Fig. 49/3).
6. Repeat the process for all beverage sizes.
7. Exit configuration mode by pressing the program button (Fig. 49/2) or the "Start & Stop" button (Fig. 49/3) for 5 seconds.
The "PGM" indicator (Fig. 49/4) goes out.
The fill times for the beverage sizes are reset to the factory settings.
Installation and service manual Dispensing valve
UFB1
26
Configuring and adjusting
1
2
PGM
WAIT
5
4
3
Fig. 48
1
PGM
WAIT
4
3
2
Fig. 49
Cornelius Deutschland GmbH
Document no. TD2004100
Version 15/03/2019, Index 0

Advertisement

Table of Contents
loading

Table of Contents